Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CONCRETE SYSTEMS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CONCRETE SYSTEMS INC. in 14 COMMERCIAL STREET, HUDSON, NH 03051 (NAICS 327390). OSHA activity number 341003069.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Concrete Systems INC. — free Get an email when a new federal OSHA severe-injury report for Concrete Systems INC. is published. One employer, no account, unsubscribe in one click.
Site address
14 COMMERCIAL STREET
City
HUDSON
State
NH
ZIP
03051
Mailing
14 COMMERCIAL STREET, HUDSON, NH 03051
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
100
Ownership type
A

6 citations on file for this inspection.

1910.179 L01

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 10, 2016
Abate by
Feb 17, 2016
Penalty
Initial $6,930 · Current $5,000 Reduced
29 CFR 1910.179(l)(1): A preventive maintenance program based on the crane manufacturer's recommendations was not established:    (a)   A preventative maintenance program was not developed for the overhead cranes.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $6930

1910.179 L03 III D

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 10, 2016
Abate by
Feb 17, 2016
Penalty
Initial $3,960 · Current $0 Reduced
29 CFR 1910.179(l)(3)(iii)(d): Pendant control stations shall be kept clean and function labels kept legible.    (A)  Pendant control stations were not kept as required.  -
Recent events (2)
  • — I (S) $0
  • — Z (S) $3960

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Feb 10, 2016
Abate by
Feb 17, 2016
Penalty
Initial $2,970 · Current $0 Reduced
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing and labeling.    (a) The man made electrical outlet box was not listed and labeled for its use of an extension cord.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2970

1910.179 L03 I

Repeat Gravity 10 1 instance 6 exposed
Issued
Feb 10, 2016
Abate by
Feb 17, 2016
Penalty
Initial $13,860 · Current $8,000 Reduced
29 CFR 1910.179(l)(3)(i): Unsafe condition(s) disclosed during the frequent or periodic inspection(s) required by 29 CFR 1910.179(j) were not corrected before operation of the crane(s) was resumed:    (a) Building #30 - The overhead gantry cranes were not repaired after deficiency's were found during periodic inspections in 2014.    Concrete Systems Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29CFR1910.179(l)(3)(I), which was contained in OSHA inspection number 994582, citation number 01, item number 003, and was affirmed as a final order on 07/15/15, with respect to a workplace located at 14 Commercial Street, Hudson, NH 03051.
Recent events (2)
  • — I (R) $8000
  • — Z (R) $13860

1910.303 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 10, 2016
Abate by
Feb 17, 2016
Penalty
Initial $7,920 · Current $7,000 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:    (a) Building 30 - Electrical service feed were covered by concrete and labeling was illegible.      Concrete Systems Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29CFR1910.303(b)(1), which was contained in OSHA inspection number 994582, citation number 01, item number 008a and was affirmed as a final order on 07/15/15, with respect to a workplace located at 14 Commercial Street, Hudson, NH, 03051.
Recent events (2)
  • — I (S) $7000
  • — Z (R) $7920

1910.303 F02

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 10, 2016
Abate by
Feb 17, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2):   Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.    (A)  The service feeders and branch circuits as their disconnecting means or overcurrent device were not legibly marked as required.  -  Concrete Systems Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29CFR1910.303(f)(2), which was contained in OSHA inspection number 994582, citation number 01, item number 008b, and was affirmed as a final order on 07/15/15, with respect to a workplace located at 14 Commercial Street, Hudson, NH, 03051.
Recent events (2)
  • — I (S) $0
  • — Z (R) $0

View Concrete Systems INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341003069.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.