MERRILL, WI —
OSHA Inspection: MERRILL FAB INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MERRILL FAB INC. in 1211 WEST WATER ST., MERRILL, WI 54452 (NAICS 332710). OSHA activity number 341003101.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MERRILL FAB INC.
- Site address
- 1211 WEST WATER ST.
- City
- MERRILL
- State
- WI
- ZIP
- 54452
- Mailing
- 1211 WEST WATER ST., MERRILL, WI 54452
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 68
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.252 B02 III
- Issued
- Dec 14, 2015
- Abate by
- Dec 23, 2015
- Penalty
- Initial $2,380 · Current $2,083 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: a) On or about October 21, 2015 employees operating machinery in the I-beam an assembly bays were exposed to welding rays without the protection of noncombustible and/or flameproof screens or shield positioned to block the rays.
Recent events (2)
- — I (S) $2082.5
- — Z (S) $2380
1910.147 C06 I A
- Issued
- Dec 14, 2015
- Abate by
- Jan 5, 2016
- Penalty
- Initial $595 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(A): The periodic inspections of the energy control procedure were not performed by an authorized employee other than the one utilizing the energy control procedure being inspected: a) On or about October 21, 2015 the employer did not have an authorized employee as specified under the energy control standard perform their periodic inspections of energy control procedures.
Recent events (2)
- — I (O) $0
- — Z (O) $595
More inspections at Merrill FAB INC.
View Merrill FAB INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341003101.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.