Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MERRILL FAB INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MERRILL FAB INC. in 1211 WEST WATER ST., MERRILL, WI 54452 (NAICS 332710). OSHA activity number 341003101.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Merrill FAB INC. — free Get an email when a new federal OSHA severe-injury report for Merrill FAB INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MERRILL FAB INC.
Site address
1211 WEST WATER ST.
City
MERRILL
State
WI
ZIP
54452
Mailing
1211 WEST WATER ST., MERRILL, WI 54452
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
68
Ownership type
A

2 citations on file for this inspection.

1910.252 B02 III

Serious Gravity 5 8 instances 20 exposed
Issued
Dec 14, 2015
Abate by
Dec 23, 2015
Penalty
Initial $2,380 · Current $2,083 Reduced
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:    a) On or about October 21, 2015 employees operating machinery in the I-beam an assembly bays were exposed to welding rays without the protection of noncombustible and/or flameproof screens or shield positioned to block the rays.
Recent events (2)
  • — I (S) $2082.5
  • — Z (S) $2380

1910.147 C06 I A

Deleted Other-than-serious 10 instances 20 exposed
Issued
Dec 14, 2015
Abate by
Jan 5, 2016
Penalty
Initial $595 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i)(A): The periodic inspections of the energy control procedure were not performed by an authorized employee other than the one utilizing the energy control procedure being inspected:  a) On or about October 21, 2015 the employer did not have an authorized employee as specified under the energy control standard perform their periodic inspections of energy control procedures.
Recent events (2)
  • — I (O) $0
  • — Z (O) $595

View Merrill FAB INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341003101.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.