ZANESVILLE, OH —
OSHA Inspection: CARL RITTBERGER SR. INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CARL RITTBERGER SR. INC. in 1900 LUTZ LANE, ZANESVILLE, OH 43701 (NAICS 311612). OSHA activity number 341003523.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CARL RITTBERGER SR. INC.
- Site address
- 1900 LUTZ LANE
- City
- ZANESVILLE
- State
- OH
- ZIP
- 43701
- Mailing
- 1900 LUTZ LANE, ZANESVILLE, OH 43701
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311612
- Employees
- 17
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C01
- Issued
- Dec 8, 2015
- Abate by
- Jan 10, 2016
- Penalty
- Initial $1,800 · Current $900 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a. On or before October 21, 2015, the employer did not establish an energy control program, thereby exposing employees to caught-in, struck-by, or other hazards.
Recent events (2)
- — I (S) $900
- — Z (S) $1800
1910.212 A01
- Issued
- Dec 8, 2015
- Abate by
- Jan 10, 2016
- Penalty
- Initial $2,520 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. a. On or before October 21, 2015, in the grind room where employees use the bowl chopper to mix and grind meats, the bowl chopper was not guarded, resulting in the amputation of an employee's fingers.
Recent events (2)
- — I (S) $1260
- — Z (S) $2520
1910.303 B01 VIII
- Issued
- Dec 8, 2015
- Abate by
- Dec 26, 2015
- Penalty
- Initial $1,800 · Current $900 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(viii): Other factors that contribute to the practical safeguarding of persons using or likely to come in contact with the equipment. a. On the bowl chopper where the discharge motor was replaced and wires spliced, the conduit was removed exposing the splice, thereby exposing the employees to an electrical contact hazard. b. On the left side of the bowl chopper where the electrical wiring went into the side of the machine, the metal clad electrical conduit was broken/rusted apart, exposing the wiring to the sharp edges of the conduit and wet conditions, thereby exposing the employees to an electrical contact hazard.
Recent events (2)
- — I (S) $900
- — Z (S) $1800
1910.303 C03 I
- Issued
- Dec 8, 2015
- Abate by
- Dec 26, 2015
- Penalty
- Initial $1,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(c)(3)(i): Conductors shall be spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy. Soldered splices shall first be spliced or joined to be mechanically and electrically secure without solder and then soldered. All splices and joints and the free ends of conductors shall be covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose. a. On the bowl chopper where the discharge motor was replaced and wires spliced, the wires were spliced and taped with electrical tape which does not meet the insulation equivalent of the conductors, thereby exposing the employees to an electrical contact hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $1800
1910.305 E01
- Issued
- Dec 8, 2015
- Abate by
- Dec 26, 2015
- Penalty
- Initial $2,520 · Current $1,260 Reduced
General-duty citation text
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures. Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations shall be installed so as to prevent moisture or water from entering and accumulating within the enclosures and shall be mounted so there is at least 6.35-mm (0.25-in.) airspace between the enclosure and the wall or other supporting surface. However, nonmetallic enclosures may be installed without the airspace on a concrete, masonry, tile, or similar surface. The enclosures shall be weatherproof in wet locations. a. On the wall behind the bowl chopper, the 240 volt 3-phase electrical box enclosure was open on the bottom where the conductors entered, exposing the employees to an electrical contact hazard.
Recent events (2)
- — I (S) $1260
- — Z (S) $2520
More inspections at Carl Rittberger SR. INC.
View Carl Rittberger SR. INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311612)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341003523.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.