Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACME PARTS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ACME PARTS, INC. in 901 ELTON ST., BROOKLYN, NY 11208 (NAICS 332913). OSHA activity number 341003648.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Acme Parts, INC. — free Get an email when a new federal OSHA severe-injury report for Acme Parts, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ACME PARTS, INC.
Site address
901 ELTON ST.
City
BROOKLYN
State
NY
ZIP
11208
Mailing
901 ELTON ST., BROOKLYN, NY 11208
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332913
Employees
26
Ownership type
A

12 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 3 instances 3 exposed
Issued
May 18, 2016
Abate by
Jun 7, 2016
Penalty
Initial $7,000 · Current $5,500 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:     Location: ACME Parts, Inc. fabrication     On or about 02/05/2016        The employer did not implement a written energy control program consisting of training prior to any servicing or maintenance on machines, such as but not limited to.            (a) Employees were repairing the Acme Gridley Machine #604, and did not utilize a energy control program.            (b) Employees were  repairing the Acme Gridley machine #602, and did not utilize a energy control program.                (c)  Employees were repairing the Davenport Machine #510, and did not utilize a energy control program.
Recent events (3)
  • — F (S) $5500
  • — C (S) $7000
  • — Z (S) $7000

1910.147 C04 I

Serious Gravity 10 3 instances 3 exposed
Issued
May 18, 2016
Abate by
May 31, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): The employer did not ensure procedures were developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  Location: ACME Parts, Inc. fabrication   On or about 02/05/2016      The employer did not implement a written energy control procedure consisting of training prior to any servicing or maintenance on machines, such as but not limited to.          (a) Employees were repairing the Acme Gridley Machine #604, and did not implement written energy control procedures.          (b) Employees were repairing the Acme Gridley machine #602, and did no implement written energy control procedures.              (c)  Employees were repairing the Davenport Machine #510, and did not implement written energy control procedures.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C05 I

Serious Gravity 10 3 instances 3 exposed
Issued
May 18, 2016
Abate by
May 31, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(i): The employer did not ensure that locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware shall be provided by the employer for isolating, securing or blocking of machines or equipment from energy sources.  Location: ACME Parts, Inc. fabrication   On or about 02/05/2016      The employer did not provide the hardware  necessary to lock out tag out machinery, such as but not limited to.           (a) Employees were repairing the ACME Gridley Machine #604, and did not utilize hardware to isolate the energy sources.         (b) Employees were repairing the ACME Gridley machine #602, and did not utilize hardware to isolate the energy sources.              (c)  Employees were repairing the Davenport Machine #510, and did not utilize hardware to isolate the energy sources.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 10 3 instances 3 exposed
Issued
May 18, 2016
Abate by
May 31, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees Location: ACME Parts, Inc. fabrication   On or about 02/05/2016  The employer did not train employees on energy control program requirements prior to any servicing or maintenance on machines, such as but not limited to.              (a) Employees were repairing the Acme Gridley Machine #604 and were not trained on the energy control program.            (b) Employees were repairing the Acme Gridley machine #602 and were not trained on the energy control program.             (c)  Employees were repairing the Davenport Machine #510 and were not trained on the energy control program.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.212 A01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
May 18, 2016
Abate by
May 31, 2016
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Location: Acme Parts Inc., Machine Shop  On or about: 02/05/2016   a) Employee was working within the point of operation of Swassy Turret lathe machine #4.
Recent events (3)
  • — F (S) $0
  • — C (S) $4900
  • — Z (S) $4900

1910.212 A03 II

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
May 18, 2016
Abate by
May 31, 2016
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.212(a)(3)(ii): The  point of operation of machines whose operation exposed an employee to injury, was not guarded:  Location: ACME Parts Inc.  On or about 02/05/2016             a) Employee was using a Warner and Swassy turret machine lathe #4 without a guard in place.
Recent events (3)
  • — F (S) $0
  • — C (S) $4900
  • — Z (S) $4900

1910.215 A01

Serious Gravity 5 2 instances 2 exposed
Issued
May 18, 2016
Abate by
May 31, 2016
Penalty
Initial $3,500 · Current $2,600 Reduced
29 CFR 1910.215(a)(1): Abrasive wheel used on grinding machinery were not used with safety guard    Location: ACME Parts, Inc. Tool Room      On or about 02/05/2016              a) Employee was using a surface grinding machine without a guard in place.
Recent events (3)
  • — F (S) $2600
  • — C (S) $3500
  • — Z (S) $3500

1910.219 C02 I

Serious Gravity 5 1 instance 1 exposed
Issued
May 18, 2016
Abate by
May 31, 2016
Penalty
Initial $3,500 · Current $2,600 Reduced
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting    Location: Acme Parts Inc., Machine Shop    On or about: 02/05/2016     a)  Employee was exposed to the rotational side of the exposed horizontal shaft of the Warner & Swassy turret lathe No. 4.
Recent events (3)
  • — F (S) $2600
  • — C (S) $3500
  • — Z (S) $3500

1910.219 C04 II

Serious Gravity 5 3 instances 3 exposed
Issued
May 18, 2016
Abate by
May 31, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered:  Location: Acme Parts Inc., Machine Shop  On or about: 02/05/2016   a)  Employee was exposed to an unused keyway of the horizontal shaft of the Warner & Swassy turret lathe No. 4.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
May 18, 2016
Abate by
May 31, 2016
Penalty
Initial $3,500 · Current $2,600 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    Location: Acme Parts Inc., Machine Shop    On or about: 02/05/2016     a)  Employee was exposed to the rotating belt of horizontal shaft of the Warner & Swassy turret lathe No. 4.
Recent events (3)
  • — F (S) $2600
  • — C (S) $3500
  • — Z (S) $3500

1910.242 B

Serious Gravity 5 1 instance 12 exposed
Issued
May 18, 2016
Abate by
May 31, 2016
Penalty
Initial $3,500 · Current $2,600 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i    Location: Acme Parts Inc. Machine Shop    On or about 02/05/2016     a) Employees use compressed air to clean machined shavings and oil off the machined pieces.
Recent events (3)
  • — F (S) $2600
  • — C (S) $3500
  • — Z (S) $3500

1910.303 G02 I

Serious Gravity 10 1 instance 1 exposed
Issued
May 18, 2016
Abate by
May 31, 2016
Penalty
Initial $4,900 · Current $2,600 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    Location: ACME Parts, Inc. Machine Shop     On or about 02/05/2016                (a)  Employees were exposed to live parts at 208 volts or more while working on the Davenport Machine #510. Electrical panel door was open, while the employee was working adjacent to live parts.
Recent events (3)
  • — F (S) $2600
  • — C (S) $4900
  • — Z (S) $4900

View Acme Parts, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341003648.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.