MEDINA, OH —
OSHA Inspection: GASKO FABRICATED PRODUCTS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GASKO FABRICATED PRODUCTS in 4049 RIDGE ROAD, MEDINA, OH 44256 (NAICS 423840). OSHA activity number 341008258.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GASKO FABRICATED PRODUCTS
- Site address
- 4049 RIDGE ROAD
- City
- MEDINA
- State
- OH
- ZIP
- 44256
- Mailing
- 4049 RIDGE ROAD, MEDINA, OH 44256
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423840
- Employees
- 20
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C04 I
- Issued
- Nov 24, 2015
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about October 20, 2015, the employer did not ensure employees were utilizing the procedures for the safe application, usage, and removal of energy controls during die setup operations of a Perkins Machine Company, 5 ton full revolution mechanical power press, Model 5-C, Serial No. 43531, known as Press A-2. Energy sources include, but not limited to, electric, pneumatic and mechanical power.
Recent events (2)
- — I (S) $1820
- — Z (S) $2800
1910.147 C06 I
- Issued
- Nov 24, 2015
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about October 20, 2015, the employer did not conduct and/or certify annual periodic inspections of each authorized employees responsibilities under the energy control procedures to ensure the procedures and requirements of the standards were being followed. Machines and equipment include, but are not limited to; a Perkins Machine Company, 5 ton full revolution mechanical power press, Model 5-C, Serial No. 43531, known as Press A-2. Energy sources include, but not limited to, electric, pneumatic and mechanical power.
Recent events (2)
- — I (S) $1820
- — Z (S) $2800
1910.147 D02
- Issued
- Nov 24, 2015
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: On or about October 20, 2015, the employer did not ensure employees performing die setup operations turned off and shut down a Perkins Machine Company, 5 ton full revolution mechanical power press, Model 5-C, Serial No. 43531, known as Press A-2, using the established energy control procedures for the press. Energy sources include, but not limited to, electric, pneumatic and mechanical power.
Recent events (2)
- — I (S) $1820
- — Z (S) $2800
1910.147 D03
- Issued
- Nov 24, 2015
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: On or about October 20, 2015, the employer did not ensure employees performing die setup operations isolated the electrical, pneumatic, and mechanical energy sources of a Perkins Machine Company, 5 ton full revolution mechanical power press, Model 5-C, Serial No. 43531, known as Press A-2. Energy sources include, but not limited to, electric, pneumatic and mechanical power.
Recent events (2)
- — I (S) $1820
- — Z (S) $2800
1910.147 D04 I
- Issued
- Nov 24, 2015
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On or about October 20, 2015, the employer did not ensure employees performing die setup operations affixed lockout devices to each energy isolation device of a Perkins Machine Company, 5 ton full revolution mechanical power press, Model 5-C, Serial No. 43531, known as Press A-2. Energy sources include, but not limited to, electric, pneumatic, and mechanical power.
Recent events (2)
- — I (S) $1820
- — Z (S) $2800
1910.147 D06
- Issued
- Nov 24, 2015
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished: On or about October 20, 2015, the employer did not ensure employees performing die setup operations verified isolation and de-energization of a of a Perkins Machine Company, 5 ton full revolution mechanical power press, Model 5-C, Serial No. 43531, known as Press A-2, had been accomplished. Energy sources include, but not limited to, electric, pneumatic, and mechanical power.
Recent events (2)
- — I (S) $1820
- — Z (S) $2800
1910.219 F03
- Issued
- Nov 24, 2015
- Penalty
- Initial $1,600 · Current $1,040 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: On or about October 23, 2015, the employer did not ensure the sprockets and chain used to transmission power to the Press A-2 material feeder was effectively guarded.
Recent events (2)
- — I (S) $1040
- — Z (S) $1600
More inspections at Gasko Fabricated Products
View Gasko Fabricated Products's full OSHA safety record →
More inspections in this industry (NAICS 423840)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341008258.