PORT CHARLOTTE, FL —
OSHA Inspection: OWEN-AMES-KIMBALL COMPANY
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of OWEN-AMES-KIMBALL COMPANY in MIDWAY BLVD AND EDGEWATER DR, PORT CHARLOTTE, FL 33952 (NAICS 237310). OSHA activity number 341011088.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OWEN-AMES-KIMBALL COMPANY
- Site address
- MIDWAY BLVD AND EDGEWATER DR
- City
- PORT CHARLOTTE
- State
- FL
- ZIP
- 33952
- Mailing
- 11941 FAIRWAY LAKES DR, FORT MYERS, FL 33913
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237310
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.651 J02
- Issued
- Apr 18, 2016
- Penalty
- Initial $2,100 · Current $1,260 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a. On Edgewater Drive, west of the intersection with Midway Blvd, employees of Stevens and Layton, Inc. were exposed to a struck by hazard while installing a 10 inch sanitary sewer pipe and a 12 inch reclaim water pipe, in that, excavators were driven on top of the spoil placed right at the edge of the north excavation wall which was about 10 feet deep and 250 feet long, on or about 10/21/2015.
Recent events (2)
- — I (S) $1260
- — Z (S) $2100
1926.652 A01
- Issued
- Apr 18, 2016
- Penalty
- Initial $4,900 · Current $2,940 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraphs (b) or (c) of this section: a. On Midway Blvd, at the south side of the intersection with Edgewater Drive, employees of Stevens and Layton, Inc. were exposed to possible cave-ins, in that, shoring or sloping was not used to protect employees when installing a 10 inch sanitary sewer pipe in a trench excavation with type "C" soil which was 10 feet deep, 45 feet long and 17 feet wide, on or about 10/21/2015. b. On Edgewater drive west of the intersection with Midway Blvd, employees of Stevens and Layton, Inc. were exposed to possible cave-ins, in that, shoring or sloping was not used to protect employees when installing a 10 inch sanitary sewer pipe and a 12 inch reclaim water pipe in a trench excavation with type "C" soil which was 10 feet deep, 250 feet long and 15 feet wide, on or about 10/21/2015.
Recent events (2)
- — I (S) $2940
- — Z (S) $4900
More inspections at Owen-Ames-Kimball Company
View Owen-Ames-Kimball Company's full OSHA safety record →
More inspections in this industry (NAICS 237310)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341011088.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.