OSHA Inspection: MANUEL MOLINO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MANUEL MOLINO in 3071 W. SOUTHLAKE BLVD., SOUTH LAKE, TX 76092 (NAICS 423330). OSHA activity number 341015667.

Watch Manuel Molino — free Get an email when a new federal OSHA severe-injury report for Manuel Molino is published. One employer, no account, unsubscribe in one click.
Establishment
MANUEL MOLINO
Site address
3071 W. SOUTHLAKE BLVD.
City
SOUTH LAKE
State
TX
ZIP
76092
Mailing
4950 NOLAN ST., FORT WORTH, TX 76119
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423330
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.405 A02 II I

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $1200.00
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage:  On the east side of the building, an extension cord that was used to connect the generator to the power source was not protected from vehicular damage, exposing employees to electrical shock and/or burns.
Recent events (1)
  • — Z (S) $1200

1926.405 G02 IV

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $1200.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  On the east side of the building, an extension cord that was providing electrical power to various power tools had no strain relief, allowing the outer sheathing to be pulled back with the internal wiring exposed, exposing employees to electrical shock hazards.
Recent events (1)
  • — Z (S) $1200

1926.416 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  On the east side of the building, an extension cord which had outer sheathing that was worn was being used to provide electrical power to various power tools on the site, exposing employees to electrical hazards.
Recent events (1)
  • — Z (S) $0

1926.501 B11

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  On the east side of the building, employees were working on a steep roof without using any type of fall protection, exposing employees to falls of more than 6 feet to the ground below.
Recent events (1)
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1600.00 · Current $1600.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (0.9 m) above the upper landing surface being accessed:  On the east side of the building, the aluminum extension ladder used by employees to access the work area did not have side rails extended at least three feet above the edge of the roof.  Employees were exposed to falls of approximately 16 feet to the concrete below.