Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROLFY'S MAINTENANCE LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of ROLFY'S MAINTENANCE LLC in 65 COLUMBIA RD., MORRISTOWN, NJ 07960 (NAICS 561790). OSHA activity number 341018885.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rolfy'S Maintenance LLC — free Get an email when a new federal OSHA severe-injury report for Rolfy'S Maintenance LLC is published. One employer, no account, unsubscribe in one click.
Site address
65 COLUMBIA RD.
City
MORRISTOWN
State
NJ
ZIP
07960
Mailing
1140 MARY ST. APT. 3, ELIZABETH, NJ 07201
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561790
Employees
7
Ownership type
A

5 citations on file for this inspection.

1903.19 D01

Other-than-serious 1 instance 1 exposed
Issued
Sep 19, 2016
Abate by
Oct 6, 2016
Penalty
Initial $400 · Current $400
29 CFR 1903.19(d)(1): The employer did not submit to the Agency, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required:  a) Center Court at Morristown, 65 Columbia Rd., Morristown, NJ      1) Citation 1, Item 2a, 29 CFR 1910.1200(e)(1) which was issued on 03/21/2016.  Abatement for this         item was due 05/05/2016.      2) Citation 1, Item 2b, 29 CFR 1910.1200(h)(1) which was issued on 03/21/2016.  Abatement for this item was due 05/05/2016.   The violation occurred on or about 10/15/2015
Recent events (1)
  • — Z (O) $400

1910.1000 A02

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 21, 2016
Penalty
Initial $2,800 · Current $2,800

Hazardous substances C730

29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of carbon monoxide listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 50 parts per million (ppm):  a) Center Court at Morristown, 65 Columbia Rd. Morristown, NJ   An employee who was cleaning the Men's locker room with other subcontractor employees was exposed to carbon monoxide (CO) during a 30 minute occupational exposure.  One worker had a mean calculated exposure of 1668.3 parts per million (ppm) CO (SAE= 0.143).  The present carboxyhemoglobin (COHb) in the employee's blood reached a calculated peak level of 38.9%.  Atmospheric pressure, height, weight, activity level, tobacco smoking behavior and other factors were taken into account.  The 8-hour Time Weighted Average (TWA) exposure was 104.3ppm CO (SAE 0.141) which is 2.09 times the OSHA Permissible Exposure Limit (PEL) of 50 ppm CO.  Conditions occurred on or about 10/15/2015.
Recent events (1)
  • — Z (S) $2800

1910.1000 E

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 21, 2016
Penalty
Initial $0 · Current $0

Hazardous substances C730

29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):  a) Center Court at Morristown, 65 Columbia Rd. Morristown, NJ  An employee who was cleaning the Men's locker room with other subcontractor employees was exposed to carbon monoxide (CO) during a 30 minute occupational exposure.  One worker had a mean calculated exposure of 1668.3 parts per million (ppm) CO (SAE= 0.143).  The present carboxyhemoglobin (COHb) in the employee's blood reached a calculated peak level of 38.9%.  Atmospheric pressure, height, weight, activity level, tobacco smoking behavior and other factors were taken into account.  The 8-hour Time Weighted Average (TWA) exposure was 104.3ppm CO (SAE 0.141) which is 2.09 times the OSHA Permissible Exposure Limit (PEL) of 50 ppm CO.  Conditions occurred on or about 10/15/2015.  Effective means of abatement include, but are not limited to:     a) Limit the use of gasoline power washer to outdoor activities,     b) Use an electric power washer for all indoor cleaning tasks.
Recent events (1)
  • — Z (S) $0

1910.1200 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 21, 2016
Abate by
May 5, 2016
Penalty
Initial $2,800 · Current $2,800

Hazardous substances C730

29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a)  Center Court of Morristown, 65 Columbia Rd. Morristown, NJ  The employer did not develop and implement a written hazard communication program for employees exposed to hazardous chemicals including, but not limited to, carbon monoxide as a product of combustion while operating a gasoline powered power washer indoors.  One employee was admitted to the hospital due to an overexposure to carbon monoxide.  Conditions occurred on or about 10/15/2105.
Recent events (1)
  • — Z (S) $2800

1910.1200 H01

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 21, 2016
Abate by
May 5, 2016
Penalty
Initial $0 · Current $0

Hazardous substances C730

29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) Center Court at Morristown, 65 Columbia Rd. Morristown, NJ  The employer did not provided effective information and training to employees who were operating a gasoline powered power washer indoors and exposed to carbon monoxide.   One employee was admitted to the hospital after an overexposure to carbon monoxide.  Conditions occurred on or about 10/15/2015.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341018885.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.