OSHA Inspection: ALICE RADIATOR SERVICE, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ALICE RADIATOR SERVICE, INC. in 408 W. FRONT ST., ALICE, TX 78332 (NAICS 811118). OSHA activity number 341021152.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alice Radiator Service, INC. — free Get an email when a new federal OSHA severe-injury report for Alice Radiator Service, INC. is published. One employer, no account, unsubscribe in one click.
Site address
408 W. FRONT ST.
City
ALICE
State
TX
ZIP
78332
Mailing
P.O. BOX 1112, ALICE, TX 78333
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811118
Employees
7
Ownership type
A

4 citations on file for this inspection.

1910.134 E01

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 9, 2015
Abate by
Jan 6, 2016
Penalty
Initial $1,020 · Current $612 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  At this establishment, the employer did not provide a medical evaluation for employees who wear half-face respirators during painting operations.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

1910.134 F02

Serious Gravity 1 1 instance 3 exposed
Issued
Dec 9, 2015
Abate by
Jan 6, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  The employer did not provide employees a fit test prior to their use of a respirator during painting operations at this establishment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 9, 2015
Abate by
Jan 6, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:   At this establishment in the middle of the repair shop facing north in a tool hanging area, a half-face respirator was stored improperly exposing the respirator to sunlight, dirt, dust, and grease.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 1 1 instance 4 exposed
Issued
Dec 9, 2015
Abate by
Jan 6, 2016
Penalty
Initial $1,020 · Current $612 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:   The employer did not supply an eye wash station. Employees were exposed to corrosive chemicals, such as but not limited to, hydrochloric acid at this establishment.
Recent events (2)
  • — I (S) $612
  • — Z (S) $1020

View Alice Radiator Service, INC.'s full OSHA safety record →