Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LUIS NONATO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LUIS NONATO in 6880 BONNIE BRAE LANE, COLUMBUS, OH 43235 (NAICS 238160). OSHA activity number 341025138.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Luis Nonato — free Get an email when a new federal OSHA severe-injury report for Luis Nonato is published. One employer, no account, unsubscribe in one click.
Establishment
LUIS NONATO
Site address
6880 BONNIE BRAE LANE
City
COLUMBUS
State
OH
ZIP
43235
Mailing
7262 FALL CREEK LANE, COLUMBUS, OH 43235
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

1 citation on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Nov 20, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  a. Located at 6880 Bonnie Brae Lane in Columbus, Ohio: employees were performing roofing work from the roof of a two story, eight on twelve pitched, residential house without the use of fall protection, thereby exposing employees to a maximum fall hazard of approximately seventeen feet.