HOT SPRINGS, AR —
OSHA Inspection: C.B. MASONRY, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of C.B. MASONRY, INC in 4129 CENTRAL AVENUE, HOT SPRINGS, AR 71913 (NAICS 238140). OSHA activity number 341028009.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- C.B. MASONRY, INC
- Site address
- 4129 CENTRAL AVENUE
- City
- HOT SPRINGS
- State
- AR
- ZIP
- 71913
- Mailing
- PO BOX 46140, LITTLE ROCK, AR 72214
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 90
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 B01 I
- Issued
- Apr 4, 2016
- Abate by
- Apr 25, 2016
- Penalty
- Initial $6,930 · Current $5,000 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. Employees worked from a supported scaffold to perform masonry activities which had excessive spacing between planks of greater than 1 inch.
Recent events (2)
- — I (S) $5000
- — Z (S) $6930
1926.451 H02 II
- Issued
- Apr 4, 2016
- Abate by
- Apr 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: Employees worked from a supported scaffold while performing masonry activities which did not have toeboards erected along the edge of platforms to prevent ground level employees from being struck by overhead tools, materials, or equipment.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 B04
- Issued
- Apr 4, 2016
- Abate by
- Apr 25, 2016
- Penalty
- Initial $6,930 · Current $5,000 Reduced
General-duty citation text
29 CFR 1926.451(b)(4): Each end of a platform, which was not cleated or otherwise restrained by hooks or equivalent means, did not extend over the centerline of its support at least 6 inches: Employees worked from a supported scaffold to perform masonry activities, which had insufficient overhang of supports or cleating.
Recent events (2)
- — I (S) $5000
- — Z (S) $6930
1926.451 C01 III
- Issued
- Apr 4, 2016
- Abate by
- Apr 25, 2016
- Penalty
- Initial $6,930 · Current $5,000 Reduced
General-duty citation text
29 CFR 1926.451(c)(1)(iii): Ties, guys, braces, or outriggers were not installed to prevent the tipping of supported scaffolds in all circumstances where an eccentric load, such as a cantilevered work platform, was applied or was transmitted to the scaffold: Ties, guys, braces, or outriggers were not used for cantilevered work platform.
Recent events (2)
- — I (S) $5000
- — Z (S) $6930
1926.451 E01
- Issued
- Apr 4, 2016
- Abate by
- Apr 25, 2016
- Penalty
- Initial $6,930 · Current $5,000 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: Instance a: Employees on a supported scaffold were using the end frames of the scaffold as a means of access from the scaffold platforms. Instance b: Employees on a baker's scaffold were using the crossbraces of the scaffold as a means of access from the scaffold platform.
Recent events (2)
- — I (S) $5000
- — Z (S) $6930
1926.451 G01
- Issued
- Apr 4, 2016
- Abate by
- Apr 25, 2016
- Penalty
- Initial $6,930 · Current $5,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: An employee unloading bricks from a pallet on raised forks of a forklift was exposed to an 18 foot fall without fall protection.
Recent events (2)
- — I (S) $5000
- — Z (S) $6930
1926.451 G04 I
- Issued
- Apr 4, 2016
- Abate by
- Apr 25, 2016
- Penalty
- Initial $6,930 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: Employees were working from a supported scaffold which did not have a guardrail system installed along all open sides and ends of the scaffold.
Recent events (2)
- — I (S) $0
- — Z (S) $6930
More inspections at C.B. Masonry, INC
View C.B. Masonry, INC's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in AR
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341028009.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.