OSHA Inspection: VULCAN INDUSTRIES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of VULCAN INDUSTRIES, INC. in 300 DISPLAY DRIVE, MOODY, AL 35004 (NAICS 337215). OSHA activity number 341028439.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vulcan Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Vulcan Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
300 DISPLAY DRIVE
City
MOODY
State
AL
ZIP
35004
Mailing
300 DISPLAY DRIVE, MOODY, AL 35004
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337215
Employees
250
Ownership type
A

9 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 1, 2016
Abate by
Apr 13, 2016
Penalty
Initial $7,000 · Current $5,500 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a)  On or about 10/07/2015 - Facility, energy control procedures had not been developed and documented for employees performing servicing and maintenance for equipment such as, but not limited to, tube saws, band saws, presses, punches, drill press, CNC and milling machines.  An employee was injured when clearing a jam from a tube saw without locking out the equipment.
Recent events (2)
  • — I (S) $5500
  • — Z (S) $7000

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 1, 2016
Abate by
Apr 13, 2016
Penalty
Initial $5,000 · Current $4,000 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    (a) On or about 10/14/2015 - Main plant, paint line area behind the office area, an eye wash station was not provided for employees transferring corrosives including Ferric Chloride, Sulfuric Acid, and Sodium Hydroxide Solution.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5000

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 1, 2016
Abate by
Apr 13, 2016
Penalty
Initial $4,000 · Current $2,500 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a)  On or about 10/14/2015 - Main Plant, Tool Room, South Bend Horizontal Lathe, the rotating chuck was not guarded.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4000

1910.217 B07 II

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 1, 2016
Penalty
Initial $4,000 · Current $2,500 Reduced
29 CFR 1910.217(b)(7)(ii): Mechanical power press(s) using part revolution clutches were not provided with a red color stop control, which would immediately deactivate the clutch and apply the brake, override any other control, and require use of the operating (tripping) means selected to reactivate the clutch:    (a) On or about 10/14/2015 - Main Plant, Wire Department, Amada Press #207, the e-stop was not operational.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4000

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 1, 2016
Penalty
Initial $4,000 · Current $2,500 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    (a) On or about 10/14/2015 - Main Plant, Fabrication Area, Bridgeport Drill Press, the pulley was not guarded exposing employees to amputation hazards when turning the machine on or off.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4000

1910.219 E01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:  (a) On or about 10/14/2015 - Main Plant, Fabrication Area, Bridgeport Drill Press, the horizontal belts were not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 1, 2016
Penalty
Initial $4,000 · Current $2,500 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    (a)  On or about 10/14/2015 - Main Plant, Warehouse (East Wall), the 480-volt disconnects (8) were blocked by charging machines and metal racks.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4000

1910.305 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 1, 2016
Penalty
Initial $3,000 · Current $2,000 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a) On or about 10/14/2015 - Main Plant, Warehouse (East Wall), the 480-volt disconnects had unused openings.     (b) On or about 10/14/2015 - Main Plant, Fabrication Area, Press #219, the 220-volt disconnect had an unused opening.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3000

1910.305 G01 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 1, 2016
Abate by
Apr 13, 2016
Penalty
Initial $4,000 · Current $2,500 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    (a)  On or about 10/14/2015 - Main Plant, Warehouse, an extension cord was being used to power the banding equipment.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4000