Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNITED CONSTRUCTION BROTHERS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of UNITED CONSTRUCTION BROTHERS, INC. in 11 W. 37TH ST, NEW YORK, NY 10018 (NAICS 236220). OSHA activity number 341031565.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United Construction Brothers, INC. — free Get an email when a new federal OSHA severe-injury report for United Construction Brothers, INC. is published. One employer, no account, unsubscribe in one click.
Site address
11 W. 37TH ST
City
NEW YORK
State
NY
ZIP
10018
Mailing
230 W 129TH ST APT12E, NEW YORK, NY 10027
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
11
Ownership type
A

2 citations on file for this inspection.

1926.404 F06

Serious Gravity 5 2 instances 1 exposed
Issued
Jan 25, 2016
Abate by
Feb 2, 2016
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.   a) Ground floor near stairway and 3rd floor stairway:  On or about November 3, 2015  The outlets attached to the light stringer were not grounded.
Recent events (1)
  • — Z (S) $1600

1926.405 A02 II E

Serious Gravity 5 2 instances 1 exposed
Issued
Jan 25, 2016
Abate by
Feb 2, 2016
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:   a) Ground floor near stairway and 3rd floor stairway:  On or about November 3, 2015  The bulbs on the light string were not protected.
Recent events (1)
  • — Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341031565.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.