Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SWANSON WIPER CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SWANSON WIPER CORPORATION in 645 LEEWARD COURT WEST, OSHKOSH, WI 54901 (NAICS 322299). OSHA activity number 341033314.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Swanson Wiper Corporation — free Get an email when a new federal OSHA severe-injury report for Swanson Wiper Corporation is published. One employer, no account, unsubscribe in one click.
Site address
645 LEEWARD COURT WEST
City
OSHKOSH
State
WI
ZIP
54901
Mailing
645 LEEWARD COURT WEST, OSHKOSH, WI 54901
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322299
Employees
100
Ownership type
A

6 citations on file for this inspection.

1910.147 C06 I C

Serious Gravity 5 1 instance 6 exposed
Issued
Jan 26, 2016
Abate by
Mar 2, 2016
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected:    a)    On or about 11/3/2015, the company did not provide for periodic inspections of their energy control program in their LOCKOUT/TAGOUT PROGRAM, CODE: S104.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.212 A01

Serious Gravity 5 3 instances 12 exposed
Issued
Jan 26, 2016
Abate by
Mar 11, 2016
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a)    On or about 11/3/2015, Machine #26 had an exposed slitter blade and ingoing nip points on the draw rolls with guards out of adjustment. Nip points were not protected from the bottom on the beaver tails where the napkins are transferred.    b)    On or about 11/3/2015, the TMC wrapper in-feed safety interlock switch was defeated.    c)    On or about 11/3/2015, the Galbreath Baler was operational with the guard door open.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2975

1910.219 D01

Serious Gravity 5 3 instances 6 exposed
Issued
Jan 26, 2016
Abate by
Apr 1, 2016
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a)    On or about 11/3/2015, #26 machine drive belt and pulley system were not guarded.    b)    On or about 11/3/2015, #25 and #4 back stand unwind belts and pulleys were not guarded.
Recent events (2)
  • — I (S) $1428
  • — Z (S) $2380

1910.219 E03 I

Serious Gravity 5 3 instances 6 exposed
Issued
Jan 26, 2016
Abate by
Apr 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):      a)    On or about 11/3/2015, #26 machine drive belt and pulley system were not guarded.    b)    On or about 11/3/2015, #25 and #4 back stand unwind belts and pulleys were not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 F01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 26, 2016
Abate by
Mar 2, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii):  a)    On or about 11/3/2015, Machine #26 did not have the gear cover guard in place for one of the draw rolls on the top deck.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 F03

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 26, 2016
Abate by
Mar 2, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed:  a)    On or about 11/3/2015, Machine #26 had an unguarded chain and sprocket approximately 7" from the yellow door guard frame and another one on the backside of the separator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Swanson Wiper Corporation's full OSHA safety record →