Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VIRGINIA TRANSFORMER CORP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VIRGINIA TRANSFORMER CORP in 3770 POLE LINE ROAD BLG 37, POCATELLO, ID 83201 (NAICS 335311). OSHA activity number 341034650.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Virginia Transformer Corp — free Get an email when a new federal OSHA severe-injury report for Virginia Transformer Corp is published. One employer, no account, unsubscribe in one click.
Site address
3770 POLE LINE ROAD BLG 37
City
POCATELLO
State
ID
ZIP
83201
Mailing
3770 POLE LINE ROAD, BLDG 37, POCATELLO, ID 83201
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335311
Employees
225
Ownership type
A

10 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 12 exposed
Issued
Mar 14, 2016
Abate by
Apr 7, 2016
Penalty
Initial $7,000 · Current $4,000 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that a safety latch on an overhead crane was not serviceable, exposing employees to a crushing or struck-by hazard:    a) C-bay  #6 overhead crane: On November 11, 2015 and at times prior thereto the safety latches on the duplex hook  on the 50T Shaw-box were damaged and sprung away from the hooks.    Note) Certification and documentation of corrective action ARE required for this item.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $7000

1910.179 B05

Serious Gravity 10 1 instance 10 exposed
Issued
Mar 14, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.179(b)(5): When a crane has more than one hoisting unit, each hoist did not have its rated load marked on it or its load block and this marking was not clearly legible from the ground or floor:  a) E-bay, #11 overhead crane: On November 3, 2015 and at times prior thereto the applicable rated load markings were not in place on either the main 15 ton hoist or the auxiliary 5 ton hoist load blocks on the Shawbox 15 ton crane.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 H01 I

Serious Gravity 10 1 instance 12 exposed
Issued
Mar 14, 2016
Abate by
Apr 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.179(h)(1)(i): Sheave grooves were not smooth and free from surface defects which could cause rope damage:  a) E-bay #11 overhead crane: On November 3, 2015 and at times prior thereto a sheave on the Shawbox 15 ton load block assembly was damaged.  One of the outer most sheaves had a significant gouge in it.      Note) Certification and documentation of corrective action ARE required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 J02 III

Serious Gravity 10 1 instance 10 exposed
Issued
Mar 14, 2016
Abate by
Apr 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(2)(iii): Frequent inspections on hooks did not include a monthly inspection and certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected:  a) Facility: On November 3, 2015 and at times prior thereto frequent inspection and a monthly certification record of the inspection were not completed on overhead cranes.  This included, but may not be limited to the C-bay 50T Judson (#7), E-bay 15/5T Shaw-box (#11), and the E-bay 15T Judson (#12).       Note) Certification of corrective action IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 L03 I

Serious Gravity 10 1 instance 10 exposed
Issued
Mar 14, 2016
Abate by
Apr 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.179(l)(3)(i): Any unsafe conditions disclosed by the inspection requirements of paragraph (j) of this section were not corrected before operation of the crane was resumed:  a) E-bay, #11 overhead crane: On November 3, 2016 and at times prior thereto the Shawbox 15 ton overhead crane continued in use while the rated load block markings on the main and auxiliary hoists were missing.  This condition was not identified and/or corrected as part of the frequent inspections (daily/monthly) performed on the crane.    b) E-bay, #11 overhead crane: On November 3, 2016 and at times prior thereto the Shawbox 15 ton overhead crane continued in use while a sheave on the main hoist load block had a significant gouge in it.  This condition was not identified and/or corrected as part of the frequent inspections (daily/monthly) performed on the crane.    c)  C-bay, #6 overhead crane: On November 3, 2016 and at times prior thereto the Shawbox 50 ton overhead crane continued in use while the safety latches on the duplex hook were not serviceable.  This condition was not identified and/or corrected as part of the frequent inspections (daily/monthly) performed on the crane.    Note) Certification and documentation of corrective action IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 M01

Serious Gravity 10 1 instance 10 exposed
Issued
Mar 14, 2016
Abate by
Apr 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.179(m)(1): A thorough inspection of all ropes was not made at least once a month and a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier for the ropes which were inspected was not kept on file where readily available to appointed personnel:   a) Facility: On November 3, 2015 and at times prior thereto a certification record of the hoisting rope inspections were not completed every month.  This included, but may not be limited to the C-bay 50T Judson (#7), E-bay 15/5T Shaw-box (#11), and the E-bay 15T Judson (#12).        Note) Certification of corrective action IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 A04

Serious Gravity 5 1 instance 10 exposed
Issued
Mar 14, 2016
Abate by
Apr 7, 2016
Penalty
Initial $4,400 · Current $2,200 Reduced
29 CFR 1910.215(a)(4): On offhand grinding machines work rests were not kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest:  a) E-bay, location E20R: On November 3, 2015 and at times prior thereto adjustment for the work rest was not maintained on the Jet 8 inch bench grinder.   Note) Certification of corrective action IS required for this item.
Recent events (2)
  • — I (S) $2200
  • — Z (S) $4400

1910.215 B09

Serious Gravity 5 1 instance 10 exposed
Issued
Mar 14, 2016
Abate by
Apr 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top exceed one-fourth inch:  a) E-bay, column E20R: On November 3, 2015 and at times prior thereto the adjustment for the tongue guard was not maintained on the Jet 8 inch bench grinder.     Note) Certification of corrective action IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.252 B02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 14, 2016
Abate by
Apr 7, 2016
Penalty
Initial $4,400 · Current $2,200 Reduced
29 CFR 1910.252(b)(2)(iii):  Workers or other persons adjacent to the welding areas were not protected from the rays by noncombustible or flameproof screens or shields or were not required to wear appropriate goggles:  a) E-bay, column E15R: On November 3, 2015 and at times prior thereto an employee performed grinding activities adjacent to welding operations.  A protective screen was not in place, nor was appropriate eyewear worn to shield the employee from arc welding rays.  Note) Certification of corrective action IS required for this item.
Recent events (2)
  • — I (S) $2200
  • — Z (S) $4400

1910.253 B05 II I

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 14, 2016
Abate by
Apr 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(5)(ii)(I): Cylinders were not kept far enough away from the actual welding or cutting operation so that sparks, hot slag, or flame will not reach them, or fire-resistant shields were not provided:  a) E-bay, column E26L: On November 3, 2015 and at times prior thereto the plasma cutting table was located 13 feet from the storage area for acetylene cylinders.   Fire-resistant shields were not provided.  Note) Certification of corrective action IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Virginia Transformer Corp's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341034650.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.