Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PACIFIC COMPOSITES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PACIFIC COMPOSITES, INC. in 302 WEST SOLEDAD AVE., HAGATNA, GU 96910 (NAICS 336611). OSHA activity number 341035590.

Watch Pacific Composites, INC. — free Get an email when a new federal OSHA severe-injury report for Pacific Composites, INC. is published. One employer, no account, unsubscribe in one click.
Site address
302 WEST SOLEDAD AVE.
City
HAGATNA
State
GU
ZIP
96910
Mailing
302 WEST SOLEDAD AVE., HAGATNA, GU 96910
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
3
Ownership type
A

8 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $840.00 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    (a) On November 5, 2015, inside the shop area,  Pacific Composites, Inc., did not develop and implement a written respiratory protection program for employees who are required to use respirators.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:      a. On November 5, 2015, a 3M full face respirator was being used without administering a medical evaluation to determine the employee's ability to use a respirator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:      a. On November 5, 2015, a 3M full face respirator was used without administering a fit test to ensure a good seal to protect employees from isocyanatosulphonyltoluene.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K03

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:      a. On November 5, 2015, an employee using a 3M full face respirator was not trained on the use, care and limitations of the full face respirator.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $840.00 Reduced
29 CFR 1910.305(b)(1): Unused openings in boxes, cabinets, or fittings were not effectively closed:      (a) On November 5, 2015, at the inside back wall of the boat shop, an unused opening in the main electrical panel box was not effectively closed, exposing employees to electrical and fire hazards.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.305 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:   (a) On November 5, 2015, at the south side of the boat shop (inside), the duplex junction box consisting of two 110 VAC GFCI receptacles was missing it's faceplate.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $840.00 Reduced
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following:      (a) On November 5,2015, a written hazard communication program was not developed for employees that worked with hazardous chemicals to include, but not limited to Amercoat 450H.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.212 B

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:   (a) On November 5, 2015, at the back wall of the boat shop (inside), the Ingersoll Rand air compressor was not securely anchored to prevent walking or moving, exposing employees to struck-by hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341035590.