OSHA Inspection: MID SOUTH FEEDS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MID SOUTH FEEDS, INC. in 225 NEWCASTLE STREET, BRUNSWICK, GA 31520 (NAICS 311119). OSHA activity number 341036820.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MID South Feeds, INC. — free Get an email when a new federal OSHA severe-injury report for MID South Feeds, INC. is published. One employer, no account, unsubscribe in one click.
Site address
225 NEWCASTLE STREET
City
BRUNSWICK
State
GA
ZIP
31520
Mailing
700 GLOUCESTER STREET SUITE 101, BRUNSWICK, GA 31520
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311119
Employees
6
Ownership type
A

4 citations on file for this inspection.

1910.147 C07 I

Serious Gravity 10 1 instance 3 exposed
Issued
Mar 16, 2016
Abate by
Apr 11, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:   a)    In the Brunswick feed manufacturing facility: On November 3, 2015, and at times prior thereto, the employer exposed employees to amputation hazards, in that affected and authorized employees were not provided adequate training regarding the energy-control program elements including, but not limited to, authorized employee description, affected employee description, and the limitations placed on employees of each designation prior to servicing and maintenance of machinery and equipment not limited to replacing a V-belt on a 201 feed-mill conveyor.
Recent events (1)
  • — Z (S) $2800

1910.157 C01

Other-than-serious 1 instance 5 exposed
Issued
Mar 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:   a)   In the Brunswick feed manufacturing facility: On November 3, 2015, and at times prior thereto, the employer exposed its employees to fire-related hazards, in that a portable fire extinguisher adjacent to the warehouse was situated upright near a work-table edge subjecting it to inadvertent damage and malfunctioning.
Recent events (1)
  • — Z (O) $0

1910.157 G01

Other-than-serious 1 instance 4 exposed
Issued
Mar 16, 2016
Abate by
Apr 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:   a)   In the Brunswick feed manufacturing facility: On November 3, 2015, and at times prior thereto, the employer exposed its employees to fire-related hazards, in that employees were not provided an educational training program to familiarize each worker with the general principles of fire-extinguisher use, and the hazards associated with incipient-stage firefighting.
Recent events (1)
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 5 exposed
Issued
Mar 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:   a)   In the Brunswick feed manufacturing facility breaker room: On November 3, 2015, and at times prior thereto, the employer exposed its employees to electrical hazards, in that excessive debris not limited to Igloo-type water containers, a chair and a bicycle inhibited ready access to operational-equipment knife switches.
Recent events (1)