Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AIR SOLUTIONS HEATING AND COOLING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AIR SOLUTIONS HEATING AND COOLING, INC. in 2575 EDISON AVE, JACKSONVILLE, FL 32204 (NAICS 332322). OSHA activity number 341037216.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AIR Solutions Heating and Cooling, INC. — free Get an email when a new federal OSHA severe-injury report for AIR Solutions Heating and Cooling, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2575 EDISON AVE
City
JACKSONVILLE
State
FL
ZIP
32204
Mailing
2575 EDISON AVE, JACKSONVILLE, FL 32204
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
9
Ownership type
A

5 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 16, 2015
Abate by
Dec 4, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level was not guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides:  a. On November 5, 2015, in the warehouse, the elevated storage area did not have a guardrail, exposing employees to a 10 feet fall hazard.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 16, 2015
Abate by
Dec 4, 2015
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a. On November 5, 2015, in the warehouse, the Lockformer notcher did not have an adequate guard at the point of operation, exposing employees to an amputation hazard.  b. On November 5, 2015, in the warehouse, the Jet drill press did not have a point of operation guard, exposing employees to the hazard of being cut by the drill bit.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.212 B

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 16, 2015
Abate by
Dec 4, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.212(b): Machines designed for a fixed location were not securely anchored to prevent walking or moving:  a. On November 5, 2015, in the warehouse, the Jet drill press not anchored to the floor was top heavy, exposing employees to the hazard of being struck by the drill press.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.22 D01

Other-than-serious 1 instance 8 exposed
Issued
Nov 16, 2015
Abate by
Dec 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): In every building or other structure, or part thereof, used for mercantile, business, industrial, or storage purposes, the loads approved by the building official were not marked on plates of approved design which were not supplied and securely affixed by the owner of the building, or his duly authorized agent, in a conspicuous place in each space to which they relate:
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 2 instances 8 exposed
Issued
Nov 16, 2015
Abate by
Nov 23, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment:  a. On November 5, 2015, in the warehouse, there were two electrical panel boxes that were not kept clear in order to access the panel box.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341037216.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.