Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VIRGINIA TRANSFORMER CORP

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of VIRGINIA TRANSFORMER CORP in 3770 POLE LINE ROAD, BLDG 37, POCATELLO, ID 83201 (NAICS 335311). OSHA activity number 341040160.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Virginia Transformer Corp — free Get an email when a new federal OSHA severe-injury report for Virginia Transformer Corp is published. One employer, no account, unsubscribe in one click.
Site address
3770 POLE LINE ROAD, BLDG 37
City
POCATELLO
State
ID
ZIP
83201
Mailing
3770 POLE LINE ROAD, BLDG 37, POCATELLO, ID 83201
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335311
Employees
225
Ownership type
A

11 citations on file for this inspection.

1910.134 D01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 12, 2016
Abate by
May 6, 2016
Penalty
Initial $2,805 · Current $1,400 Reduced
29 CFR 1910.134(d)(1)(ii): The employer did not select and use a NIOSH-certified respirator in compliance with the conditions of its certification:  a) Sandblasting Area.: On or about December 1, 2015 and at times prior, Employees were sand blasting with a Clemco Hood while using Flextral breathing air hoses.  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2805

1910.1200 H03

Serious Gravity 1 1 instance 3 exposed
Issued
Apr 12, 2016
Abate by
May 6, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3): The employee training did not include the requirements of 29 CFR 1910.1200(h)(3)(i) through (h)(3)(iv):  (a) Paint Booth: On or about December 1, 2015 and at times prior, employees were not trained in the hazards associated with working with paints, thinners and primers.  Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 D01 III

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 12, 2016
Abate by
May 6, 2016
Penalty
Initial $2,805 · Current $1,400 Reduced
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  a) Paint Booth: On or about December 1, 2015 and at times prior, Employees were painting transformers in the paint booth while wearing respirators.  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2805

1910.134 D03 III B 2

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 12, 2016
Abate by
May 6, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator that would ensure cartridges were changed before the end of their service life:  a) Paint Booth: On or about December 1, 2015 and at times prior, Employees were painting transformers in the paint booth while wearing respirators.  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 G01 I A

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 12, 2016
Abate by
May 6, 2016
Penalty
Initial $2,805 · Current $1,400 Reduced
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:  a) Paint Booth: On or about December 1, 2015 and at times prior, Employees were painting transformers in the paint booth while wearing respirators.  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2805

1910.134 K03

Deleted Serious Gravity 1 1 instance 1 exposed
Issued
Apr 12, 2016
Abate by
May 6, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace:  a) Sand Blasting Area: On or about December 1, 2015 and at times prior, Employees were sand blasting with an air supplied Clemco Hood.  Abatement certification required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 I01 II

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 12, 2016
Abate by
Jun 15, 2016
Penalty
Initial $7,000 · Current $2,400 Reduced
29 CFR 1910.134(i)(1)(ii): Breathing air did not meet requirements for Grade D breathing air as described in the ANSI/Compressed Gas Association Commodity Specification G-7.1-1989:  a) Sand Blasting Area: On or about December 1, 2015 and at times prior, Employees were sand blasting with an air supplied Clemco Hood.  Employer did not have a CO or high temp monitor for an oil lubricated compressor and did not ensure grade D breathing air.  Abatement certification and documentation required for this item.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $7000

1910.134 I07

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Apr 12, 2016
Abate by
May 6, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both:  a) Sand Blasting Area: On or about December 1, 2015 and at times prior, Employees were sand blasting with an air supplied Clemco Hood.  Abatement certification and documentation required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.252 B02 III

Serious Gravity 5 1 instance 10 exposed
Issued
Apr 12, 2016
Abate by
May 6, 2016
Penalty
Initial $4,675 · Current $2,400 Reduced
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not required to wear appropriate goggles to protect them from the rays when noncombustible or flameproof screens or shields were not used:    (a) Fabrication Area: On or about December 1, 2015, and at times prior, employees were welding transformers with Miller MIG welder with other workers in adjacent areas.    NOTE: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $2400
  • — Z (S) $4675

1910.1000 D02 I

Serious Gravity 5 1 instance 12 exposed
Issued
Apr 12, 2016
Abate by
Aug 15, 2016
Penalty
Initial $5,610 · Current $3,000 Reduced

Hazardous substances 06850731152016201840

29 CFR 1910.1000(d)(2)(i): An employee was exposed to iron oxide fume, manganese fume, chromium fume, nickel fume, and copper fume listed in the Z tables in excess of the cumulative exposure limit:  a) Fabrication Area: On or about December 1, 2015 and at times prior, welder(s) cutting steel with a Hypertherm Pro Ti plasma cutter was exposed to iron oxide fume concentration of 7.10 milligrams/cubic meter; manganese fume concentration of 0.34 milligrams/cubic meter; copper fume concentration of 0.02 milligrams/cubic meter; chromium fume concentration of 0.40 milligrams/cubic meter; nickel fume concentration of 0.18 milligrams/cubic meter; and copper fume 0.07 concentration of milligrams/cubic meter.  The sum or cumulative exposure of contaminants exceeded unity for an exposure severity of 1.64 or 164% of the combined permissible exposure limits (PEL).  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5610

1910.1000 E

Serious Gravity 5 1 instance 12 exposed
Issued
Apr 12, 2016
Abate by
Aug 15, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 06850731152016201840

29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):  a) Fabrication Area: On or about December 1, 2015 and at times prior, welder(s) cutting steel with a Hypertherm Pro Ti plasma cutter was exposed to iron oxide fume concentration of 7.10 milligrams/cubic meter; manganese fume concentration of 0.34 milligrams/cubic meter; copper fume concentration of 0.02 milligrams/cubic meter; chromium fume concentration of 0.40 milligrams/cubic meter; nickel fume concentration of 0.18 milligrams/cubic meter; and copper fume 0.07 concentration of milligrams/cubic meter.  The sum or cumulative exposure of contaminants exceeded unity for an exposure severity of 1.64 or 164% of the combined permissible exposure limits (PEL).  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Virginia Transformer Corp's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341040160.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.