OPP, AL —
OSHA Inspection: B & S WELDING SERVICES
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of B & S WELDING SERVICES in 100 HILLCREST, OPP, AL 36467 (NAICS 332999). OSHA activity number 341043487.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- B & S WELDING SERVICES
- Site address
- 100 HILLCREST
- City
- OPP
- State
- AL
- ZIP
- 36467
- Mailing
- 100 HILLCREST, OPP, AL 36467
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 4
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.253 B02 II
- Issued
- Dec 15, 2015
- Penalty
- Initial $1,600 · Current $1,125 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons: a)B & S Welding Service: On or about November 3rd, 2015 and prior to, employee(s) were exposed to explosion and struck-by hazards from compressed oxygen tanks, mixed welding gas and acetylene tanks being stored and not secured from being knocked over.
Recent events (2)
- — I (S) $1125
- — Z (S) $1600
1910.253 B02 IV
- Issued
- Dec 15, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: a)B & S Welding Service: On or about November 3rd, 2015 and prior to, employee(s) were exposed to explosion and struck-by hazards from compressed oxygen tanks, mixed welding gas and acetylene tanks that did not have valve protection cap on stored full tanks exposing employees to explosion and fire hazards while changing tanks out. Compressed Gas Association Pamphlet G-1-1966, 4.2.8 states Valve protection for in the design, should be mechanically attached except when cylinders are in actual use.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B04 III
- Issued
- Dec 15, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour. a)B & S Welding Service: On or about November 3rd, 2015 and prior to, employee(s) were exposed to explosion and struck-by hazards from compressed oxygen tanks, mixed welding gas and acetylene tanks being stored next to each other.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.254 B04 IV
- Issued
- Dec 15, 2015
- Penalty
- Initial $1,600 · Current $1,125 Reduced
General-duty citation text
29 CFR 1910.254(b)(4)(iv): Terminals for welding leads were not protected from accidental contact by personnel or metal objects: a) Miller welder #1: On or about November 3rd, 2015 the employer exposed employee(s) to electrical shock, burns and electrocution hazards from unguarded or uncovered welding leads from the working and electrode leads connected to Miller 480 volt welder machine. b) Lincoln welder #1: On or about November 3rd, 2015 the employer exposed employee(s) to electrical shock, burns and electrocution hazards from unguarded or uncovered welding leads from the working and electrode leads connected to Lincoln 480 volt welder machine.
Recent events (2)
- — I (S) $1125
- — Z (S) $1600
1910.1200 E01
- Issued
- Dec 15, 2015
- Abate by
- Dec 23, 2015
- Penalty
- Initial $0 · Current $0
0070X100
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a)Facility wide: On or about November 3rd, 2015, and prior to, the employer exposed employees to chemicals without implementing a written Hazard Communication Program and exposed employee to chemicals including but not limited to: Compressed oxygen gas cylinders, compressed mixed gas cylinders, compressed acetylene gas cylinders and Lucas Heavy Duty Oil Stabilizer.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01 I
- Issued
- Dec 15, 2015
- Abate by
- Dec 23, 2015
- Penalty
- Initial $0 · Current $0
0070X100
General-duty citation text
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present, using an identity that was referenced on the appropriate material safety data sheet: a)Facility wide: On or about November 3rd, 2015, and prior to, the employer exposed employees to chemicals with out maintaining a Chemical Inventory List or list hazardous chemicals including but not limited to: Compressed oxygen gas cylinders, compressed mixed gas cylinders, compressed acetylene gas cylinders and Lucas Heavy Duty Oil Stabilizer.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 G08
- Issued
- Dec 15, 2015
- Abate by
- Dec 23, 2015
- Penalty
- Initial $0 · Current $0
0070X100
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain copies of the required material safety data sheets for each hazardous chemical in the workplace: a)B & S Welding Services: On or about November 3rd, 2015, and prior to, the employer exposed employees to chemicals without maintaining Safety Data Sheets (SDS) hazardous chemicals including but not limited to: Compressed oxygen gas cylinders, compressed mixed gas cylinders, compressed acetylene gas cylinders and Lucas Heavy Duty Oil Stabilizer.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 H01
- Issued
- Dec 15, 2015
- Abate by
- Dec 23, 2015
- Penalty
- Initial $0 · Current $0
0070X100
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a)B & S Welding Services: On or about November 3rd, 2015 and prior to, initial training on a written hazard communication program was not documented for employee(s) exposed to hazards including but not limited to: Compressed oxygen gas cylinders, compressed mixed gas cylinders, compressed acetylene gas cylinders and Lucas Heavy Duty Oil Stabilizer.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 332999)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341043487.