ARLINGTON HEIGHTS, IL —
OSHA Inspection: BOGDAN TRZINSKI DBA MBR CONSTRUCTION, CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BOGDAN TRZINSKI DBA MBR CONSTRUCTION, CORP. in 701 N. CHESTNUT, ARLINGTON HEIGHTS, IL 60005 (NAICS 238160). OSHA activity number 341044170.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BOGDAN TRZINSKI DBA MBR CONSTRUCTION, CORP.
- Site address
- 701 N. CHESTNUT
- City
- ARLINGTON HEIGHTS
- State
- IL
- ZIP
- 60005
- Mailing
- 4412 RIVER ROAD APT. 2W, SCHILLER PARK, IL 60176
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Dec 16, 2015
- Abate by
- Dec 22, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) Employees were exposed to eye injury while operating pneumatic nail guns without eye protection. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (S) $1600
1926.501 B13
- Issued
- Dec 16, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b): a) Employees were exposed to the hazard of falling while working from a roof deck having a pitch of approximately 10/12 and a ground to eave height of about 13 feet. No abatement certification or documentation required for this violation.
Recent events (1)
- — Z (S) $2800
1926.552 A01
- Issued
- Dec 16, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.552(a)(1): The employer did not comply with the manufacturer's specifications and limitations applicable to the operation of all hoists and elevators: a) A material hoist was used for climbing to reach the roof surface where roofing work was being conducted. No abatement certification or documentation required for this violation.
Recent events (1)
- — Z (S) $1600
1926.1053 B12
- Issued
- Dec 16, 2015
- Abate by
- Dec 22, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive side-rails: a) During re-roofing work, portable aluminum extension ladders were provided for employee use where the ladders or the employees could contact electrical service drops (power lines) having a voltage of 120/240. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (S) $2000
1926.503 B01
- Issued
- Dec 16, 2015
- Abate by
- Dec 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record: a) The employer did not prepare written certification records related to employee fall protection training. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).