DES PLAINES, IL —
OSHA Inspection: PERFECT TEMPERATURE CONTROL, INC. DBA FAB-RITE SHEET METAL
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PERFECT TEMPERATURE CONTROL, INC. DBA FAB-RITE SHEET METAL in 74 BRADROCK DRIVE, DES PLAINES, IL 60018 (NAICS 332322). OSHA activity number 341045029.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 74 BRADROCK DRIVE
- City
- DES PLAINES
- State
- IL
- ZIP
- 60018
- Mailing
- 74 BRADROCK DRIVE, DES PLAINES, IL 60018
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 35
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C01
- Issued
- Jan 26, 2016
- Abate by
- Feb 22, 2016
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) On November 9, 2015, the employer did not establish a program consisting of an energy control procedure, employee training, and periodic inspections, to protect employees from the unexpected energizing, startup or release of stored energy when performing any servicing or maintenance on equipment, including coil-duct machines. In accordance with 29CFR 1903.19(d), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $2450
- — Z (S) $3500
1910.147 C04 I
- Issued
- Jan 26, 2016
- Abate by
- Feb 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On November 9, 2015, the employer did not develop, document, and utilize procedures for the control of potentially hazardous energy when employees perform servicing or maintenance on equipment, including coil-duct machines. In accordance with 29CFR 1903.19(d), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I
- Issued
- Jan 26, 2016
- Abate by
- Feb 29, 2016
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: a) On November 9, 2015, the employer did not ensure in house maintenance employees were adequately trained and/or knowledgeable in the recognition of servicing and/or maintenance activities that require machine or equipment shutdown and lockout to be performed to prevent injury from operating equipment, including coil-duct machines. In accordance with 29CFR 1903.19(d), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $2450
- — Z (S) $3500
1910.178 L04 III
- Issued
- Jan 26, 2016
- Abate by
- Feb 22, 2016
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) On November 9, 2015, the employer did not conduct an evaluation of each powered industrial truck operator's performance at least once every three years. In accordance with 29CFR 1903.19(d), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $1470
- — Z (S) $2100
1910.212 A03 II
- Issued
- Jan 26, 2016
- Abate by
- Feb 29, 2016
- Penalty
- Initial $3,500 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) On November 24, 2015, the employer did not guard the point of operation at the FECO Roto die, which exposed employees to an amputation hazard when parts being bent were held with both hands and the machine was operated using the foot treadle. In accordance with 29CFR 1903.19(d), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $2450
- — Z (S) $3500
More inspections at Perfect Temperature Control, INC. DBA Fab-Rite Sheet Metal
View Perfect Temperature Control, INC. DBA Fab-Rite Sheet Metal's full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341045029.