OSHA Inspection: MASON WIRELESS SOLUTIONS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MASON WIRELESS SOLUTIONS in 8510 BOBLSED TRAIL, MORRISON, CO 80465 (NAICS 237990). OSHA activity number 341046738.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mason Wireless Solutions — free Get an email when a new federal OSHA severe-injury report for Mason Wireless Solutions is published. One employer, no account, unsubscribe in one click.
Site address
8510 BOBLSED TRAIL
City
MORRISON
State
CO
ZIP
80465
Mailing
240 WYANDOT STREET, DENVER, CO 80223
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237990
Employees
42
Ownership type
A

3 citations on file for this inspection.

1910.132 F01 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 6, 2016
Abate by
Jan 12, 2016
Penalty
Initial $4,900 · Current $4,900
29 CFR 1910.132(f)(1)(iv): Employee(s) required to use PPE by this section were not trained to know the limitations of PPE:   a) On or about November 4, 2015 and at times prior, an employee fell approximately 25 feet from a telecommunication tower. The employee was wearing a personal fall arrest system that was hooked on a cross-brace of the tower. The employee was not properly instructed to the limitations of the PPE in which the cross-brace was used as an anchorage connector that was not capable of withstanding a 5,000-pound load as required in the ANSI Z359.1-2007 (Safety Requirements for Personal Fall Arrest Systems, Subsystems and Components) Section 3.2.5.1.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $4900

1910.268 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 6, 2016
Abate by
Jan 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.268(g)(1): The employer did not ensure that safety belts and straps were provided and used when work was performed at positions more than 4 feet above the ground, on poles, and on towers:   a) On or about November 4, 2015 and at times prior, an employee fell approximately 25 feet from a telecommunication tower. The employee's positioning device system was hooked on the cross-brace of the tower that was in the process of being removed. The employee fell as soon as the bolt was removed from the cross-brace. The supervisor was working with the employee on the tower and did not ensure that the positioning device system was used correctly.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.135 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 6, 2016
Abate by
Jan 12, 2016
Penalty
Initial $3,500 · Current $500 Reduced
29 CFR 1910.135(a)(1): The employer did not ensure that each affected employee wear a protective helmet when working in areas where there is a potential for injury to the head from falling objects:      a) On or about November 4, 2015 and at times prior, an employee was exposed to overhead hazards while other employees were replacing cross-brace members of the tower. The employee was not wearing a head protection while directly below the working area.
Recent events (2)
  • — I (S) $500
  • — Z (S) $3500

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341046738.