OSHA Inspection: ANDERSON TULLY COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ANDERSON TULLY COMPANY in 1725 NORTH WASHINGTON, VICKSBURG, MS 39180 (NAICS 321113). OSHA activity number 341054872.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Anderson Tully Company — free Get an email when a new federal OSHA severe-injury report for Anderson Tully Company is published. One employer, no account, unsubscribe in one click.
Site address
1725 NORTH WASHINGTON
City
VICKSBURG
State
MS
ZIP
39180
Mailing
1725 NORTH WASHINGTON, VICKSBURG, MS 39180
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
160
Ownership type
A

6 citations on file for this inspection.

1910.151 C

Other-than-serious 2 instances 3 exposed
Issued
Mar 16, 2016
Abate by
Mar 22, 2016
Penalty
Initial $2,525 · Current $750 Reduced
29 CFR 1910.151(c):  Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:(a) (LOCATION) (IDENTIFY SPECIFIC OPERATION(S) AND/OR CONDITIONS)(DESCRIBE HAZARD(S) WHERE NECESSARY)
Recent events (2)
  • — I (O) $750
  • — Z (S) $2525

1910.184 I09 III

Serious Gravity 5 5 instances 2 exposed
Issued
Mar 16, 2016
Abate by
Mar 24, 2016
Penalty
Initial $4,208 · Current $2,104 Reduced
29 CFR 1910.184(i)(9): Removal from service. Synthetic web slings shall be immediately removed from service if any of the following conditions are present:    29 CFR 1910.184(i)(9)(iii): Snags, punctures, tears or cuts;    (a)   Drop Sorter - On or about November 12, 2015 employees were exposed to a struck by hazard due to polyester slings being used with snags, punctures and cuts.
Recent events (2)
  • — I (S) $2104
  • — Z (S) $4208

1910.184 I09 IV

Deleted Serious Gravity 5 5 instances 2 exposed
Issued
Mar 16, 2016
Abate by
Mar 24, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.184(i)(9): Removal from service. Synthetic web slings shall be immediately removed from service if any of the following conditions are present:  29 CFR 1910.184(i)(9)(iv): Broken or worn stitches; or  (a)   Drop Sorter - On or about November 12, 2015 employees were exposed to a struck by hazard due to polyester slings being used with broken and worn stitches.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.254 D09 I

Serious Gravity 10 90 instances 3 exposed
Issued
Mar 16, 2016
Penalty
Initial $6,930 · Current $5,344 Reduced
29 CFR 1910.254(d)(9)(i): The operator should report any equipment defect or safety hazard to his supervisor and the use of the equipment shall be discontinued until its safety has been assured. Repairs shall be made only by qualified personnel.    (a)    Ford F250 - On or about November 12, 2015 employees were exposed to an electrical shock hazard due to the leads being damaged and having insulation exposed on a welding machine. Miller Bobcat 250 Welder/Generator had visible damaged wires on both the grounding (work) cable and the electrode cable yet it was taken out of service.
Recent events (2)
  • — I (S) $5344
  • — Z (S) $6930

1910.254 D09 III

Serious Gravity 10 90 instances 3 exposed
Issued
Mar 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors shall be replaced. Joining lengths of work and electrode cables shall be done by the use of connecting means specifically intended for the purpose. The connecting means shall have insulation adequate for the service conditions.  [55 FR 13709, Apr. 11, 1990; 61 FR 9227, March 7, 1996; 70 FR 53929, Sept. 13, 2005]  (a)    Ford F250 - On or about November 12, 2015 employees were exposed to an electrical shock hazard due to the leads being damaged and having insulation exposed on a Miller Bobcat 250 Welder/Generator. Both the grounding (work) cable and the electrode cable had wires exposed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Other-than-serious 2 instances 3 exposed
Issued
Mar 16, 2016
Abate by
Mar 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.  (a)  Dip Tank - On or about November 12, 2015 employees were exposed to a potential electrical shock hazard due to broken strain relief on the Bosch Hydraulic Valve.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Anderson Tully Company's full OSHA safety record →