GREENWOOD, LA ·
OSHA Inspection: TARGET ENERGY, L.L.C.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TARGET ENERGY, L.L.C. in 8560 GREENWOOD RD., GREENWOOD, LA 71033 (NAICS 424720). OSHA activity number 341057297.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TARGET ENERGY, L.L.C.
- Site address
- 8560 GREENWOOD RD.
- City
- GREENWOOD
- State
- LA
- ZIP
- 71033
- Mailing
- 7228 WEST BERT KOUNS INDUSTRIAL LOOP, SHREVEPORT, LA 71129
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 424720
- Employees
- 29
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.106 B06
- Issued
- Jan 26, 2016
- Abate by
- Feb 13, 2016
- Penalty
- Initial $4,900 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.106(b)(6): Precautions were not taken to prevent ignition by eliminating or controlling sources of ignition. Sources of ignition include; open flames, lightning, smoking, cutting and welding, hot surfaces, frictional heat, sparks (static, electrical, and mechanical), spontaneous ignition, chemical and physical-chemical reactions, and radiant heat: On or about July 27, 2015, at the Derrick Truck Stop in Greenwood, LA; the employer did not take adequate precautions to prevent the ignition of flammable vapors or overexposure to hazardous substances while the employees were drying out gasoline tankers.
Recent events (3)
- · F (S) $2000
- · C (S) $4900
- · Z (S) $4900
1910.307 C02
- Issued
- Jan 26, 2016
- Abate by
- Feb 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.307(c)(2): 29 CFR 1910.307(c)(2): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not safe for the hazardous (classified location), nor approved for the hazardous (classified) location or the ignitable or combustible properties of the specific gas, vapor, dust or fiber that was present: On or about July 27, 2015, at the Derrick Truck Stop in Greenwood, LA; the employer allowed employee(s) to use an air blower (SuperZoom Blower, Model HL-7) that was not approved for hazardous locations to dry out gasoline tankers containing flammable vapors.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.303 B02
- Issued
- Jan 26, 2016
- Abate by
- Feb 13, 2016
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: At the Derrick Truck Stop in Greenwood, LA; the employer allowed employee(s) to operate an air/fan blower (SuperZoom Blower, Model HL-7) with power cord connected to an extension cord to dry out a gasoline tankers. The manufacturer's label on the blower states: "DO NOT USE AN EXTENSION CORD WITH THIS FAN".
Recent events (3)
- · F (S) $0
- · C (S) $4900
- · Z (S) $4900
More inspections in this industry (NAICS 424720)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341057297.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.