FLUSHING, NY —
OSHA Inspection: PAN LINK CONSTRUCTION INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PAN LINK CONSTRUCTION INC in 32-42 160TH STREET, FLUSHING, NY 11358 (NAICS 236115). OSHA activity number 341060028.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PAN LINK CONSTRUCTION INC
- Site address
- 32-42 160TH STREET
- City
- FLUSHING
- State
- NY
- ZIP
- 11358
- Mailing
- 29 BEACH ROAD, GREAT NECK, NY 11023
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 4
- Ownership type
- A
Citations
14 citations on file for this inspection.
1926.95 A
- Issued
- Nov 25, 2015
- Penalty
- Initial $2,000 · Current $1,140 Reduced
General-duty citation text
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact: a) On or about November 17, 2015- job site at 32-42 160th Street, Flushing, NY 11358 the employer permitted an employee to cut bricks with a Makita grinder without wearing eye protection. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (2)
- — I (S) $1140
- — Z (S) $2000
1926.100 A
- Issued
- Nov 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about November 17, 2015- job site at 32-42 160th Street, Flushing, NY 11358 the employer permitted his employees to work below over head masonry work without wearing a protective helmet. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.300 B01
- Issued
- Nov 25, 2015
- Abate by
- Dec 22, 2015
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) On or about November 17, 2015- job site at 32-42 160th Street, Flushing, NY 11358 the employer permitted an employee to cut bricks with a Makita 9564CV grinder that had its blade guard removed. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.405 G02 IV
- Issued
- Nov 25, 2015
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) On or about November 17, 2015- job site at 32-42 160th Street, Flushing, NY 11358 the employer permitted an employee to cut bricks with a Makita 9564CV grinder that was powered by a flexible cord set with damaged strain relief. WRITTEN ABATEMENT CERTIFICATION IS NOT REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $2000
1926.451 B01 II
- Issued
- Nov 25, 2015
- Abate by
- Dec 22, 2015
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(ii): The platform was not planked or decked as fully as possible and the remaining open space between the platform and the uprights exceeded 9.5 inches (24.1 cm): a) On or about November 17, 2015- job site at 32-42 160th Street, Flushing, NY 11358 the employer permitted their employees to perform masonry work from a tubular welded frame scaffold that was not fully planked at the work level. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.451 C02
- Issued
- Nov 25, 2015
- Abate by
- Dec 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a) On or about November 17, 2015- job site at 32-42 160th Street, Flushing, NY 11358 the employer permitted their employees to perform masonry work from a tubular welded frame scaffold that did not have base plates or mud sills installed. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Nov 25, 2015
- Abate by
- Dec 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Cross braces were used as a means of access: a) On or about November 17, 2015- job site at 32-42 160th Street, Flushing, NY 11358 the employer permitted their employees to access the working level of a tubular welded frame scaffold by climbing the cross braces and frame. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F06
- Issued
- Nov 25, 2015
- Abate by
- Dec 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section. a) On or about November 17, 2015- job site at 32-42 160th Street, Flushing, NY 11358 the employer permitted their employees to perform masonry work from a tubular welded frame scaffold that was erected around the electrical power supply line. Scaffold components were less that 2 feet away from the power line. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Nov 25, 2015
- Abate by
- Dec 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a) On or about November 17, 2015- job site at 32-42 160th Street, Flushing, NY 11358 the employer permitted their employees to perform masonry work from a tubular welded frame scaffold. approximately 15 feet above the next lower level, without fall protection. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 H02 II
- Issued
- Nov 25, 2015
- Abate by
- Dec 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: Note: This requirement does not apply to float (ship) scaffolds where an edging of 3/4 inch x 1 1/2 inch (2 x 4 cm) wood or equivalent was used in lieu of toeboards: a) On or about November 17, 2015- job site at 32-42 160th Street, Flushing, NY 11358 the employer permitted their employees to perform masonry work from a tubular welded frame scaffold, approximately 15 feet above the next lower level, that did not have toe boards and there were other employees working below. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 C02
- Issued
- Nov 25, 2015
- Abate by
- Dec 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(c)(2): Frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would secure vertical members together laterally, and the cross braces were not of such length as would automatically square: a) On or about November 17, 2015- job site at 32-42 160th Street, Flushing, NY 11358 the employer permitted their employees to perform masonry work from a tubular welded frame scaffold that was missing cross bracing. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Nov 25, 2015
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about November 17, 2015- job site at 32-42 160th Street, Flushing, NY 11358 the employer permitted their employees to perform masonry work from a vestibule roof, approximately 20 feet above the next lower level, without fall protection. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1926.1053 A07
- Issued
- Nov 25, 2015
- Abate by
- Dec 22, 2015
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1926.1053(a)(7): Ladders not designed for such use were tied or fastened together to provide longer sections: a) On or about November 17, 2015- job site at 32-42 160th Street, Flushing, NY 11358 the employer permitted their employees to perform masonry work from a platform supported by a ladder that had been wired together with another ladder to increase its length. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $1680
- — Z (S) $2800
1926.1053 B04
- Issued
- Nov 25, 2015
- Abate by
- Dec 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) On or about November 17, 2015- job site at 32-42 160th Street, Flushing, NY 11358 the employer permitted their employees to perform masonry work from a platform supported by a ladders that had been wired together with another ladder to increase its length. WRITTEN ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at PAN Link Construction INC
View PAN Link Construction INC's full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341060028.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.