Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUNSTAR FOODS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUNSTAR FOODS, INC. in 1540 12TH STREET EAST, PALMETTO, FL 34221 (NAICS 311812). OSHA activity number 341067296.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sunstar Foods, INC. — free Get an email when a new federal OSHA severe-injury report for Sunstar Foods, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SUNSTAR FOODS, INC.
Site address
1540 12TH STREET EAST
City
PALMETTO
State
FL
ZIP
34221
Mailing
1540 12TH STREET EAST, PALMETTO, FL 34221
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311812
Employees
12
Ownership type
A

10 citations on file for this inspection.

1910.23 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 1, 2016
Abate by
Apr 13, 2016
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:Note:  Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard.  a) For employees working at 1540 12th Street East located in Palmetto, as observed on or about 19 November, 2015. Employees were exposed to a fall hazard above the office. Fall height was approximately 10 feet.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.157 C04

Serious Gravity 1 1 instance 4 exposed
Issued
Apr 1, 2016
Abate by
Apr 13, 2016
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:  a) For employees working at 1540 12th Street East located in Palmetto, as observed on or about 19 November, 2015. Employees were exposed to a fire hazard in that a fire extinguisher located behind the ovens was not fully charged and in an operable condition.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.242 B

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 1, 2016
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 psi.:  a) For employees working at 1540 12th Street East located in Palmetto, as observed on or about 19 November, 2015. Employees were using compressed air to clean material and clothing that was at a pressure greater than 30 p.s.i. Air pressure that was used was approximately 114 p.s.i.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.263 E01 I

Serious Gravity 10 2 instances 2 exposed
Issued
Apr 1, 2016
Abate by
Apr 13, 2016
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.263(e)(1)(i): Mixers with external power application shall have all belts, chains, gears, pulleys, sprockets, clutches, and other moving parts completely enclosed.  a) For employees working at 1540 12th Street East located in Palmetto, as observed on or about 19 November, 2015. Employees were using 2 vertical mixers that did not have the moving hook parts enclosed.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.263 C03

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 1, 2016
Abate by
Apr 13, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.263(c)(3): Sprocket(s) and V-belt drive(s) of bakery machinery located within reach from platform(s) or passageway(s) or located within 8 feet 6 inches from the floor were not completely enclosed:  a) For employees working at 1540 12th Street East located in Palmetto, as observed on or about 19 November, 2015. Employees were using the bread bagging machine that did not have a cover or guard over the drive gear sprocket and chain.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 1, 2016
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures, or by any of the following means identified in sub-paragraphs (A)through (D) of this paragraph:  a) For employees working at 1540 12th Street East located in Palmetto, as observed on or about 19 November, 2015. At the bread molder the electrical box was missing the cover exposing energized conductors.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.303 B07 I

Serious Gravity 5 2 instances 4 exposed
Issued
Apr 1, 2016
Abate by
Apr 13, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment.  For employees working at 1540 12th Street East located in Palmetto, as observed on or about 19 November, 2015.   a) At the main power panel that housed the main breakers for the building outlets and lights, one of the breakers was removed and no cover was installed in its place.  b) At the bread mixing machine main operating panel the 2 speed timers were missing and the openings were not covered.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 2 instances 14 exposed
Issued
Apr 1, 2016
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  For employees working at 1540 12th Street East located in Palmetto, as observed on or about 19 November, 2015.   a)The main electrical panels for the building did not have sufficient access due to oven racks being stored directly in front of the panel boards. The 4 foot long oven racks were stored approximately 12 inches from the face of the panel board.  b)  The main oven electrical panels did not have sufficient access due to bread boards and molds being stored directly in front of the panel boards. The bread boards and molds were approximately touching the face of the panel board.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1910.305 A01 I

Serious Gravity 5 1 instance 12 exposed
Issued
Apr 1, 2016
Abate by
Apr 13, 2016
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.305(a)(1)(i): Metal raceways, cable armor, and other metal enclosures for conductors were not connected to all boxes, fittings, and cabinets to provide effective electrical continuity:  a) For employees working at 1540 12th Street East located in Palmetto, as observed on or about 19 November, 2015. At the main electrical panel the metal raceway was not connected to the panel. The raceway was approximately  6 inches from the top of the panel box. The electrical conductors were holding the raceway in place. The raceway was feeding an energized 120 volt outlet.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.305 G02 III

Serious Gravity 5 2 instances 1 exposed
Issued
Apr 1, 2016
Abate by
Apr 13, 2016
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a) For employees working at 1540 12th Street East located in Palmetto, as observed on or about 19 November, 2015. The electrical cord that supplied power to the moveable bread forming machine did not have strain relief at the plug and at the box connection.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

View Sunstar Foods, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341067296.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.