ALTAMONT, IL —
OSHA Inspection: IRWIN SEATING COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of IRWIN SEATING COMPANY in 610 CUMBERLAND ROAD, ALTAMONT, IL 62411 (NAICS 337127). OSHA activity number 341067833.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- IRWIN SEATING COMPANY
- Site address
- 610 CUMBERLAND ROAD
- City
- ALTAMONT
- State
- IL
- ZIP
- 62411
- Mailing
- 610 CUMBERLAND ROAD, ALTAMONT, IL 62411
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337127
- Employees
- 165
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C06 I
- Issued
- Apr 20, 2016
- Abate by
- Jun 7, 2016
- Penalty
- Initial $4,500 · Current $2,925 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: The employer did not ensure that periodic inspections of the energy control procedures were conducted at least annually.
Recent events (2)
- — I (S) $2925
- — Z (S) $4500
1910.212 A03 II
- Issued
- Apr 20, 2016
- Abate by
- Jun 7, 2016
- Penalty
- Initial $6,300 · Current $4,095 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): The following pieces of equipment lacked proper guarding at the point of operation exposing employees to amputation hazards: a.) On or about 11/19/2015, an employee using the Marvel Series 81 APC band saw to cut materials was exposed to unused portions of the blade that were not guarded. b.) On or about 11/9/2015, an employee operating the 10 ft. Accupress Press Brake was exposed to a gap larger than a 1/4 inch at the point of operation.
Recent events (2)
- — I (S) $4095
- — Z (S) $6300
1910.305 G02 III
- Issued
- Apr 20, 2016
- Abate by
- Jun 7, 2016
- Penalty
- Initial $3,600 · Current $2,340 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: The outer protective jacket on the flexible cord running to the foot control at the 02A, 10 ft. Accurepress Press Brake was damaged and separated from the strain relief device.
Recent events (2)
- — I (S) $2340
- — Z (S) $3600
More inspections at Irwin Seating Company
View Irwin Seating Company's full OSHA safety record →
More inspections in this industry (NAICS 337127)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341067833.