SAN ANTONIO, TX —
OSHA Inspection: KLN MANUFACTURING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KLN MANUFACTURING in 2 WINNCO DRIVE, SAN ANTONIO, TX 78218 (NAICS 337127). OSHA activity number 341069136.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KLN MANUFACTURING
- Site address
- 2 WINNCO DRIVE
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78218
- Mailing
- 2 WINNCO DRIVE, SAN ANTONIO, TX 78218
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337127
- Employees
- 88
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.179 H02 V
- Issued
- Mar 15, 2016
- Abate by
- Mar 28, 2016
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.179(h)(2)(v): Rope clips attached with U-bolts did not have the U-bolts on the dead or short end of the rope: Near the north wall of the shop: On or about November 19, 2015, and at times prior thereto, employees were exposed to the hazards of a malfunctioning U-bolt securing a cable supporting the transformer, as the bolt was not on the short end of the rope.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.179 J03
- Issued
- Mar 15, 2016
- Abate by
- Mar 23, 2016
- Penalty
- Initial $4,200 · Current $2,520 Reduced
General-duty citation text
29 CFR 1910.179(j)(3): Complete and periodic inspections of the crane were not performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section, depending upon its activity, severity of service, and environment. These inspections include the requirements of paragraph (j)(2) of this section, to include hooks, hoist chains, ropes, and all functional operating mechanisms, and in addition, the following items, such as bolts, rivets, drums, and damaged components: Near the north wall of the shop: On or about November 19, 2015, and at times prior thereto, employees were exposed to the hazards of a malfunctioning overhead Contrx crane, in that it had not been inspected as required, while operating a spot welder which it supported.
Recent events (2)
- — I (S) $2520
- — Z (S) $4200
1910.184 D
- Issued
- Mar 15, 2016
- Abate by
- Mar 28, 2016
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.184(d): Each day before being used, the sling and all fastenings and attachments were not inspected for damage or defects by a competent person designated by the employer: Near the north wall of the shop: On or about November 19, 2015, and at times prior thereto, employees were exposed to a struck-by hazard from the malfunction of the sling, fastenings and attachments for the overhead Contrx crane, in that it had not been inspected as required, while operating a spot welder which it supported.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.184 E02 II
- Issued
- Mar 15, 2016
- Abate by
- Apr 1, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(e)(2)(ii): Makeshift links or fasteners formed from bolts or rods, or other such attachments, were used: Near the north wall of the shop: On or about November 19, 2015, and at times prior thereto, employees were exposed to amputation injuries as they operated the spot welder, in that the fasteners on the sling chains were formed from bolts.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.184 E03 I
- Issued
- Mar 15, 2016
- Abate by
- Apr 1, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(e)(3)(i): In addition to the inspection required by paragraph (d) of this section, a thorough periodic inspection of alloy steel chain slings in use was not made on a regular basis, to be determined on the basis of (A) frequency of sling use; (B) severity of service conditions; (C) nature of lifts being made; and (D) experience gained on the service life of slings used in similar circumstances: Near the north wall of the shop: On or about November 19, 2015, and at times prior thereto, employees were exposed to amputation injuries, as the chain slings were not inspected, while employees spot welded steel frames.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.184 F01
- Issued
- Mar 15, 2016
- Abate by
- Apr 1, 2016
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.184(f)(1): Employers did not use only wire-rope slings that have permanently affixed and legible identification markings as prescribed by the manufacturer, and that indicate the recommended safe working load for the type(s) of hitch(es) used, the angle upon which it is based, and the number of legs if more than one: Near the north wall of the shop. On or about November 19, 2015, and at times prior thereto, employees were exposed to a struck-by hazard from a chain sling malfunction, while employees operated a spot welder.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.212 A01
- Issued
- Mar 15, 2016
- Abate by
- Apr 2, 2016
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Wood Shop: On or about November 19, 2015, and at times prior thereto, employees were exposed to amputation injury, while they operated the Delta drill press without a guard around the drill press bit.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.212 B
- Issued
- Mar 15, 2016
- Abate by
- Mar 28, 2016
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.212(b): Machines designed for a fixed location were not securely anchored to prevent walking or moving: Wood Shop. On or about November 19, 2015, and at times prior thereto, employees were exposed to a struck-by hazard, as they operated the Delta drill press without it being anchored to the floor.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.253 B04 III
- Issued
- Mar 15, 2016
- Penalty
- Initial $3,500 · Current $2,100 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: Main shop: On or about November 19, 2015, and at times prior thereto, employees were exposed to a fire hazard, as cylinders of oxygen were stored adjacent to cylinders of argon and acetylene.
Recent events (2)
- — I (S) $2100
- — Z (S) $3500
1910.255 C02
- Issued
- Mar 15, 2016
- Abate by
- Apr 17, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.255(c)(2): All portable welding guns, transformers and related equipment that is suspended from overhead structures, eye beams, trolleys, etc. was not equipped with safety chains or cables. Safety chains or cables were not rated to show they were capable of supporting the total shock load in the event of failure of any component of the supporting system: Near the north wall of the shop: On or about November 19, 2015, and at times prior thereto, employees were exposed to amputation and struck-by injuries, as they operated the spot welder on the portable welding machine, in that the chain and equipment supporting the bundle of welding cable did not show their rated capacities.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 E03
- Issued
- Mar 15, 2016
- Abate by
- Mar 23, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): The employer did not assure that portable fire extinguishers are subjected to an annual maintenance check: Upstairs storage area, north wall: On or about November 19, 2015, and at times prior thereto, employees were exposed to the hazards of a fire, in that the fire extinguisher on the south wall of the upstairs storage area had not been inspected in almost two years.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at KLN Manufacturing
View KLN Manufacturing's full OSHA safety record →
More inspections in this industry (NAICS 337127)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341069136.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.