Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMERICAN BRIDGE COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AMERICAN BRIDGE COMPANY in 5945 WILLIAM MILLS STREET, JACKSONVILLE, FL 32226 (NAICS 238120). OSHA activity number 341070894.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch American Bridge Company — free Get an email when a new federal OSHA severe-injury report for American Bridge Company is published. One employer, no account, unsubscribe in one click.
Site address
5945 WILLIAM MILLS STREET
City
JACKSONVILLE
State
FL
ZIP
32226
Mailing
1000 AMERICAN BRIDGE WAY, CORAOPOLIS, PA 15018
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
50
Ownership type
A

15 citations on file for this inspection.

1910.410 A01

Other-than-serious 1 instance 2 exposed
Issued
Jan 11, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.410(a)(1): Each dive team member did not have the experience or training necessary to perform assigned tasks in a safe and healthful manner, (is applicable to the construction standard by 29 CFR 1926.1076 that incorporates the General Industry requirement):       a. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, employees performing diving operations did not have the experience and training in the use of tools, equipment, systems, techniques required to perform these underwater tasks in a safe manner.
Recent events (2)
  • — I (O) $7000
  • — Z (S) $7000

1910.410 A03

Other-than-serious 1 instance 2 exposed
Issued
Jan 11, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.410(a)(3): All dive team members were not trained in cardiopulmonary resuscitation and first aid (American Red Cross standard course or equivalent):    a. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, employees performing diving operations did not have the CPR training while working in the Saint Johns River.
Recent events (2)
  • — I (O) $0
  • — Z (S) $7000

1910.410 C02

Other-than-serious 1 instance 2 exposed
Issued
Jan 11, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.410(c)(2): The designated person-in-charge did not have experience and training in the conduct of the assigned diving operation (is applicable to the standard by 29 CFR 1926.1076 which incorporates the General Industry requirement):      a. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, employees performing diving operations did not ensure the designated person-in-charge had the training and experience required to plan, perform and oversee the dive operations in a safe manner.
Recent events (2)
  • — I (O) $0
  • — Z (S) $7000

1910.421 H

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jan 11, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.421(h): Warning signal. When diving from surfaces other than vessels in areas capable of supporting marine traffic, a rigid replica of the international code flag "A" at least one meter in height was not displayed at the dive location in a manner which allows all-round visibility, and shall be illuminated during night diving operations:  a. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, the employer did not provide employees performing diving operations with the international code flag "A".
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.422 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 11, 2016
Penalty
Initial $7,000 · Current $4,500 Reduced
29 CFR 1910.422(b)(2): The means provided for exiting the water did not extend below the water surface:    a. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, the employer did not provide a means of exit below the water surface.
Recent events (2)
  • — I (S) $4500
  • — Z (S) $7000

1910.422 C01 I

Other-than-serious 1 instance 2 exposed
Issued
Jan 11, 2016
Penalty
Initial $7,000 · Current $1,100 Reduced
29 CFR 1910.422(c)(1)(i): An operational two-way voice communication system was not used between each surface supplied air or mixed-gas diver and a dive team member at the dive location, (is applicable to the construction standard by 29 CFR 1926.1082 that incorporates the General Industry requirement):      a. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, the employer did not provide employees engaged in diving operations with two-way voice communications which could be used for emergency assistance and safety related direction.
Recent events (2)
  • — I (O) $1100
  • — Z (S) $7000

1910.425 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 11, 2016
Penalty
Initial $7,000 · Current $3,500 Reduced
29 CFR 1910.425(c)(1): Each surface-supplied air diver was not continuously tended while in the water:     a. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, employees performing diving operations were not continuously tended while in the water.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $7000

1910.430 B02

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jan 11, 2016
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.430(b)(2): Air compressor intakes were not located away from areas containing exhaust or other contaminants:   a. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, the employer did not provide the dive team members, who were using a surface supplied air compressor one that was equipped with an intake located away from the internal combustion engine exhaust or other contamination source.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7000

1910.430 C01 IV

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 11, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.430(c)(1)(iv): Breathing gas supply hose(s) did not have their open ends taped, capped or plugged when not in use:  a. On or about November 16, 2015, at Blount Island Marine Terminal Berth 35, the employer did not have the open ends to the supply hoses taped, capped or plugged when they were not in use.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1910.430 J02

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 11, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.430(j)(2): Diver(s) Except when heavy gear is worn or in SCUBA diving, each diver shall wear a safety harness, (is applicable to the construction standard by 29 CFR 1926.1090 that incorporates the General Industry requirement):    a. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, the employer did not equip the diver with a safety harness.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1910.420 A

Other-than-serious 1 instance 2 exposed
Issued
Jan 11, 2016
Penalty
Initial $1,100 · Current $550 Reduced
29 CFR 1910.420(a): The employer did not develop and maintain a safe practices manual:      a. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, the employer did not maintain a safe practices manual to address the safety and health of the employees who were engaged in the diving operations.
Recent events (2)
  • — I (O) $550
  • — Z (O) $1100

1910.421 C03

Other-than-serious 1 instance 2 exposed
Issued
Jan 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.421(c)(3): An American Red Cross standard first aid handbook or equivalent and a bag type manual resuscitator was not available at the dive location, (is applicable to the construction standard by 29 CFR 1926.1081 that incorporates the General Industry requirement):        a. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, the employer did not provide a first aid book or a bag-type manual resuscitator at the dive location.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.423 D01

Other-than-serious 1 instance 2 exposed
Issued
Jan 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.423(d)(1): The following information was not recorded and maintained for each diving operation:     a. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, the employer did not record and maintain the dive team members including the designated person-in-charge for each diving operation.     b. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, the employer did not record and maintain the date, time and location for each diving operation.    c. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, the employer did not record and maintain surface or underwater conditions for each diving operation.    d. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, the employer did not record and maintain the maximum depth and bottom time for each diving operation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.430 B04

Other-than-serious 1 instance 2 exposed
Issued
Jan 11, 2016
Penalty
Initial $1,100 · Current $1,100
29 CFR 1910.430(b)(4): The output of air compressor systems was not tested for air purity every six months by means of samples taken at the connection to the distribution system:     a. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, the employer was using an air compressor to provide air to the divers and the air compressor had not been tested for output and air purity by samples taken at the air distribution system.
Recent events (2)
  • — I (O) $1100
  • — Z (O) $1100

1910.430 G01

Other-than-serious 1 instance 2 exposed
Issued
Jan 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.430(g)(1): Gauges indicating diver depth, which can be read at the dive location, were not used for all dives, (is applicable to the construction standard by 29 CFR 1926.1090 that incorporates the General Industry requirement):     a. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, the employer did not provide employees who were engaged in diving operations, gauges indicating diver depth for each dive operation.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View American Bridge Company's full OSHA safety record →