Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GLEESON CONSTRUCTORS & ENGINEERS, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GLEESON CONSTRUCTORS & ENGINEERS, LLC. in 1660 SOUTH 2ND, COSHOCTON, OH 43812 (NAICS 236220). OSHA activity number 341072247.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gleeson Constructors & Engineers, LLC. — free Get an email when a new federal OSHA severe-injury report for Gleeson Constructors & Engineers, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
1660 SOUTH 2ND
City
COSHOCTON
State
OH
ZIP
43812
Mailing
2015 E 7TH STREET, SIOUX CITY, IA 51102
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
125
Ownership type
A

3 citations on file for this inspection.

1926.300 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 16, 2015
Abate by
Dec 28, 2015
Penalty
Initial $4,590 · Current $4,590
29 CFR 1926.300(b)(2): Belts, gears, shafts, pulleys, sprockets, spindles, drums, fly wheels, chains, or other reciprocating, rotating or moving parts of equipment shall be guarded if such parts are exposed to contact by employees or otherwise create a hazard. Guarding shall meet the requirements as set forth in American National Standards Institute, B15.1-1953 (R1958), Safety Code for Mechanical Power-Transmission Apparatus.  a. In the career clothing room where an employee was mixing cement, the belt and pulley's on the electric mixer were unguarded, thereby exposing employees to a caught-in hazard.
Recent events (3)
  • — F (S) $4590
  • — C (S) $4590
  • — Z (S) $4590

1926.404 F06

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 16, 2015
Abate by
Dec 28, 2015
Penalty
Initial $2,295 · Current $2,295
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.  a. In the hallway where an employee plugged an extension cord into a temporary receptacle to provide power to a cement mixer, the ground prong was missing from the extension cord, thereby exposing the employee to an electrical contact hazard.
Recent events (3)
  • — F (S) $2295
  • — C (S) $2295
  • — Z (S) $2295

1926.760 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 16, 2015
Abate by
Dec 28, 2015
Penalty
Initial $3,825 · Current $3,825
29 CFR 1926.760(a)(1): Except as provided by paragraph (a)(3) of this section, each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems.  a. On the roof of the engine room where an employee was securing the roof decking, fall protection was not used, thereby exposing the employee to a 29 foot fall hazard.
Recent events (3)
  • — F (S) $3825
  • — C (S) $3825
  • — Z (S) $3825

View Gleeson Constructors & Engineers, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341072247.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.