Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HATHAWAY, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of HATHAWAY, INC. in 1660 SOUTH 2ND STREET, COSHOCTON, OH 43812 (NAICS 238310). OSHA activity number 341072288.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hathaway, INC. — free Get an email when a new federal OSHA severe-injury report for Hathaway, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
HATHAWAY, INC.
Site address
1660 SOUTH 2ND STREET
City
COSHOCTON
State
OH
ZIP
43812
Mailing
177 N. 18TH STREET, COSHOCTON, OH 43812
Inspection type
Unprogrammed Other (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
15
Ownership type
A

2 citations on file for this inspection.

1926.404 B01 III C

Serious Gravity 1 1 instance 5 exposed
Issued
Dec 10, 2015
Abate by
Dec 22, 2015
Penalty
Initial $1,020 · Current $714 Reduced
29 CFR 1926.404(b)(1)(iii)(C): Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, shall be visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective shall not be used until repaired.  a. At the worksite where employees used extension cords and a corded drill, inspections of the equipment were not conducted before each days use, thereby exposing employees to an electrical contact hazard.
Recent events (2)
  • — I (S) $714
  • — Z (S) $1020

1926.404 F06

Serious Gravity 1 1 instance 5 exposed
Issued
Dec 10, 2015
Abate by
Dec 22, 2015
Penalty
Initial $1,020 · Current $714 Reduced
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous.  a. In the main entrance hallway where employees plugged an extension cord into the temporary electrical receptacle to provide power to the mud mixer, the ground prong on the male end of the extension cord was missing, thereby exposing employees to an electrical contact hazard.