OKLAHOMA CITY, OK —
OSHA Inspection: QUAD/GRAPHICS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of QUAD/GRAPHICS, INC. in 6801 S. SUNNYLANE RD, OKLAHOMA CITY, OK 73135 (NAICS 323111). OSHA activity number 341078442.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUAD/GRAPHICS, INC.
- Site address
- 6801 S. SUNNYLANE RD
- City
- OKLAHOMA CITY
- State
- OK
- ZIP
- 73135
- Mailing
- 6801 S. SUNNYLANE RD, OKLAHOMA CITY, OK 73135
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 650
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.212 A01
- Issued
- Jan 29, 2016
- Abate by
- Feb 23, 2016
- Penalty
- Initial $4,250 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about November 20, 2016, and at times prior thereto, employees were allowed to operate machines that were found not having guards provided, including but not limited to the following instances: 1) At the roll ramp in the MR7 area, a roll ramp operated by hydraulics had a missing guard. 2) At the stitching machine HT 148 area, a book flipping machine with moving parts inside was not provided with interlock device. 3) In the machine shop, a shear was operated without having a blade guard. 4) In the machine shop, a manual lathe machine was operated without having a chuck guard. 5) At the Mosca strapping machine area, a conveyor belt being used without guards for the in-going nip points. Employees were exposed to amputation and crushing hazards.
Recent events (3)
- — F (S) $0
- — C (S) $4250
- — Z (S) $4250
1910.215 B09
- Issued
- Jan 29, 2016
- Abate by
- Nov 11, 2016
- Penalty
- Initial $2,550 · Current $2,550
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: On or about November 20, 2016, and at times prior thereto, in press maintenance shop employees were using an abrasive wheel grinding machines where the opening between the tongue guard and the wheel was greater one-fourth inch. Employees were exposed to struck by hazards.
Recent events (3)
- — F (S) $2550
- — C (S) $2550
- — Z (S) $2550
1910.219 P01
- Issued
- Jan 29, 2016
- Abate by
- Nov 11, 2016
- Penalty
- Initial $2,550 · Current $2,550
General-duty citation text
29 CFR 1910.219(p)(1): All power-transmission equipment shall be inspected at intervals not exceeding 60 days and be kept in good working condition at all times. On or about November 20, 2016, and at times prior thereto, the employer did not document its inspection of the pulleys and wheels associated with the pocket feeding machines every 60 days to ensure that all guards were present. Abatement documentation required for this item.
Recent events (3)
- — F (S) $2550
- — C (S) $2550
- — Z (S) $2550
1910.304 B04 II B
- Issued
- Jan 29, 2016
- Abate by
- Nov 11, 2016
- Penalty
- Initial $2,550 · Current $2,550
General-duty citation text
29 CFR 1910.304(b)(4)(ii)(B): Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle may not supply a total cord- and plug-connected load in excess of the maximum specified in Table S-4; On or about November 20, 2016, and at times prior thereto, in the M-74 Console area and break areas throughout the facility microwave ovens and pizza ovens were plugged into the same outlet device which had a current rating less than the load bring served. Abatement documentation required for this item.
Recent events (3)
- — F (O) $2550
- — C (S) $2550
- — Z (S) $2550
More inspections at Quad/Graphics, INC.