PORT ISABEL, TX —
OSHA Inspection: MVM CARPENTRY
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MVM CARPENTRY in LOT #61- HWY 100 LAS JOYAS SUBDIVISION, PORT ISABEL, TX 78578 (NAICS 238350). OSHA activity number 341079655.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MVM CARPENTRY
- Site address
- LOT #61- HWY 100 LAS JOYAS SUBDIVISION
- City
- PORT ISABEL
- State
- TX
- ZIP
- 78578
- Mailing
- P O BOX 429, PORT ISABEL, TX 78578
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Dec 9, 2015
- Abate by
- Dec 23, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): November 24, 2015, employees were exposed to fall hazards while working on a residential roof, 9 feet above ground level, without fall protection.
Recent events (2)
- — I (S) $2800
- — Z (S) $2800
1926.1053 B04
- Issued
- Dec 9, 2015
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: November 24, 2015, in the rear roof of a residential dwelling under construction, , a 6 foot A-frame ladder was used as a portable non self-supporting ladder on a roof surface, 9 feet from the ground.