OSHA Inspection: HEETER

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HEETER in 441 TECHNOLOGY DRIVE, CANONSBURG, PA 15317 (NAICS 323111). OSHA activity number 341082683.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Heeter — free Get an email when a new federal OSHA severe-injury report for Heeter is published. One employer, no account, unsubscribe in one click.
Establishment
HEETER
Site address
441 TECHNOLOGY DRIVE
City
CANONSBURG
State
PA
ZIP
15317
Mailing
441 TECHNOLOGY DRIVE, CANONSBURG, PA 15317
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
110
Ownership type
A

2 citations on file for this inspection.

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Dec 31, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   (a) Facility, Computer Station: On or before December 9, 2015, a four inch square metal box was found unsecured on the floor powering a computer.
Recent events (1)
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 1 instance 1 exposed
Issued
Dec 31, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:   (a) Facility, Computer Station: On or before December 9, 2015, a flexible cord was not connected to a four inch square box in that its connector was separated from the retention nut.
Recent events (1)
  • — Z (O) $0