OSHA Inspection: R C ROOFING SERVICES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of R C ROOFING SERVICES, LLC in 2 TUNXIS ROAD, TARIFFVILLE, CT 06081 (NAICS 238160). OSHA activity number 341089795.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R C Roofing Services, LLC — free Get an email when a new federal OSHA severe-injury report for R C Roofing Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2 TUNXIS ROAD
City
TARIFFVILLE
State
CT
ZIP
06081
Mailing
2 TREAT STREET, APT 7D, WEST HAVEN, CT 06516
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.501 B11

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 3, 2015
Abate by
Jan 22, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:  On or about 11/23/2015 at the #2 Tunxis Road Re-Roofing Project, employees were removing shingles from the roof and no fall protection system was in use.
Recent events (1)
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 3, 2015
Abate by
Jan 22, 2016
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  On or about 11/23/2015 at the #2 Tunxis Road Re-Roofing Project, employees were using an extension ladder to access and descend to and from the roof deck and the ladder did not extend 3 feet past the landing.