Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: SOLUCION LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SOLUCION LLC. in 1780 MORRIS STREET, FOND DU LAC, WI 54935 (NAICS 561310). OSHA activity number 341090249.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Solucion LLC. for free Get an email when a new federal OSHA severe-injury report for Solucion LLC. is published. One employer, no account, unsubscribe in one click.
Establishment
SOLUCION LLC.
Site address
1780 MORRIS STREET
City
FOND DU LAC
State
WI
ZIP
54935
Mailing
8936 N. POINT EXECUTIVE PARK DRIVE, HUNTERSVILLE, NC 28078
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561310
Employees
47
Ownership type
Private (A)

2 citations on file for this inspection.

1910.147 D03

Serious Gravity 10 2 instances 2 exposed
Issued
Jan 20, 2016
Abate by
Feb 3, 2016
Penalty
Initial $7,000 · Current $5,600 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:    a) On or about November 7, 2015 the employer did not ensure employees unplugged the Pot-Devin glue applicator from the electrical outlet prior to the removing glue pans from the back-side of the machine, exposing employee(s) to rotating parts from the glue rollers.     b) On or about November 7, 2015 the employer did not ensure employees unplugged the Pot-Devin glue applicator from the electrical outlet prior to using a hand tool to remove glue from the rotating roller, exposing employee(s) to in-running nip point hazards.
Recent events (2)
  • · I (S) $5600
  • · Z (S) $7000

1904.39 A02

Deleted Other-than-serious 1 instance 1 exposed
Issued
Jan 20, 2016
Abate by
Jan 28, 2016
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours:   a) The employer did not report an incident involving one employee who suffered an amputation injury to the right pinky finger on November 7, 2015 within twenty-four (24) hours to OSHA.  The employer received confirmation on November 10, 2015 that the injury involved an amputation.
Recent events (2)
  • · I (O) $0
  • · Z (O) $5000

View Solucion LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341090249.