MILLIKEN, CO ·
OSHA Inspection: KINETIC HYDROVAC SERVICES LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of KINETIC HYDROVAC SERVICES LLC in 1189 QUENTINE, MILLIKEN, CO 80543 (NAICS 213112). OSHA activity number 341091197.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KINETIC HYDROVAC SERVICES LLC
- Site address
- 1189 QUENTINE
- City
- MILLIKEN
- State
- CO
- ZIP
- 80543
- Mailing
- PO BOX 530, MILLIKEN, CO 80543
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 26
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.146 G01
- Issued
- May 27, 2016
- Abate by
- Jun 23, 2016
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146: a) Kinetic Hydrovac Services, LLC dba Kinetic Hydrovac at 1189 Quentine, Milliken, CO 80543: On or before December 3, 2015, the employer did not ensure that employees serving as entrants and/or attendees while conducting work inside permit required confined spaces, which included both biofuels pits and frac tanks, had received appropriate training. The employer failed to provide appropriate training to ensure employees acquired the understanding, knowledge, and skills necessary to work safely in permit required confined spaces.
Recent events (2)
- · I (O) $1960
- · Z (S) $2800
1910.1200 H01
- Issued
- May 27, 2016
- Abate by
- Jun 23, 2016
- Penalty
- Initial $2,100 · Current $1,470 Reduced
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Kinetic Hydrovac Services, LLC dba Kinetic Hydrovac at 1189 Quentine, Milliken, CO 80543: On or before December 3, 2015, the employer did not ensure that employees serving as entrants and/or attendees while conducting work inside permit required confined spaces, which included both biofuels pits and frac tanks, had received appropriate hazard communication training. The employer failed to provide appropriate training to ensure employees at the time of their initial assignment.
Recent events (2)
- · I (S) $1470
- · Z (S) $2100
More inspections in this industry (NAICS 213112)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341091197.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.