Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VIGOR FACILITIES DEPARTMENT

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VIGOR FACILITIES DEPARTMENT in 5555 N. CHANNEL AVE, PORTLAND, OR 97217 (NAICS 336611). OSHA activity number 341091866.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vigor Facilities Department — free Get an email when a new federal OSHA severe-injury report for Vigor Facilities Department is published. One employer, no account, unsubscribe in one click.
Site address
5555 N. CHANNEL AVE
City
PORTLAND
State
OR
ZIP
97217
Mailing
5555 N. CHANNEL AVE, PORTLAND, OR 97217
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
15
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 2 instances 50 exposed
Issued
Dec 3, 2015
Abate by
Jan 30, 2016
Penalty
Initial $3,060 · Current $2,700 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  Building 9, Machine Shop-  (a) The Dake Air Hydraulic Shop Press, Model 6-651, SN# 147876, was not guarded to prevent flying parts.  (b) The 10,000 lbs Red Dake Hydraulic Shop Press was not guarded to prevent flying parts.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $3060

1910.213 B03

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 3, 2015
Abate by
Jan 30, 2016
Penalty
Initial $2,295 · Current $2,000 Reduced
29 CFR 1910.213(b)(3): Provisions were not made to prevent woodworking machine(s) from automatically restarting upon restoration of power after power failure:  Building 9 Machine Shop- (a) The DoAll bandsaw, used to cut wood, was not equipped with an anti-restart device to prevent accidental start up.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2295

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341091866.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.