Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MR. BULTS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MR. BULTS, INC. in 7120 S JORDAN RD, ENGLEWOOD, CO 80112 (NAICS 562219). OSHA activity number 341093516.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MR. Bults, INC. — free Get an email when a new federal OSHA severe-injury report for MR. Bults, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MR. BULTS, INC.
Site address
7120 S JORDAN RD
City
ENGLEWOOD
State
CO
ZIP
80112
Mailing
7120 S JORDAN RD, ENGLEWOOD, CO 80112
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562219
Employees
25
Ownership type
A

11 citations on file for this inspection.

1910.132 A

Deleted Serious Gravity 10 1 instance 24 exposed
Issued
Jan 6, 2016
Abate by
Feb 2, 2016
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:  a)  On or about December 2, 2015, and at times prior, employees were exposed to fall hazards of greater than 13 feet when they stood on the trash which was loaded in their open top semi truck trailer in order to position a tarp to cover the load.  The employer did not ensure that these employees utilized adequate personal protective equipment that would prevent them from falling.  Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (S) $0
  • — C (S) $2800
  • — Z (S) $2800

1910.178 Q01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jan 6, 2016
Abate by
Jan 26, 2016
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel:  a)  On or about December 2, 2015, the employees were exposed to struck by hazards and/or crushing hazards in that the employer did not take the Caterpillar forklift out of service when the tires for the forktruck were in need of replacement.    b)  On or about December 2, 2015, employees were exposed to struck by hazards and/or crushing hazards in that the employer did not take the Caterpillar forklift out of service when the back up alarm failed to sound.   Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (S) $0
  • — C (S) $1600
  • — Z (S) $1600

1910.178 Q07

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 6, 2016
Abate by
Jan 14, 2016
Penalty
Initial $0 · Current $1,400
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:    (a) On or about December 2, 2015, employees operating the Caterpillar forklift were exposed to struck-by and/or crushing hazards where the fork truck was not examined before being placed in service.  The fork truck had tires in need of replacement and a non-functional backup alarm.     Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (S) $1400
  • — C (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 1 1 instance 25 exposed
Issued
Jan 6, 2016
Abate by
Jan 14, 2016
Penalty
Initial $1,200 · Current $1,000 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    a)  On or about December 2, 2015, and at times prior, employees were exposed to fire and explosion hazards in that the employer did not store the oxygen cylinders 20 feet away from the propylene cylinders and a propane tank.    Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (S) $1000
  • — C (S) $1200
  • — Z (S) $1200

1910.22 A01

Deleted Other-than-serious 1 instance 25 exposed
Issued
Jan 6, 2016
Abate by
Jan 19, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.  (a)  On or about December 2, 2015, the employer did not keep the warehouse/mechanical area free from accumulation of materials, which could cause trips, slips and fall hazards.    Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.36 G02

Other-than-serious 1 instance 25 exposed
Issued
Jan 6, 2016
Abate by
Jan 14, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.  a)  On or about December 2, 2015, the employer exposed employees to hazards associated with lack of adequate egress in that the exit located on the southwest side of the warehouse measured 16.5 inches wide.   Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.106 E09 III

Deleted Other-than-serious 2 instances 25 exposed
Issued
Jan 6, 2016
Abate by
Jan 14, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily:  (a)  On or about December 2, 2015, the employer exposed employees to fire hazards in that the covered metal receptacles containing hazardous materials, were not disposed of on a daily basis.  Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.178 L06

Other-than-serious 1 instance 2 exposed
Issued
Jan 6, 2016
Abate by
Jan 14, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  (a)  On or about December 2, 2015, and at times prior, the employer did not certify that the operator was trained and evaluated to safely operate the Caterpillar forklift.    Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.184 D

Deleted Other-than-serious 1 instance 2 exposed
Issued
Jan 6, 2016
Abate by
Jan 14, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.184(d): Each day before being used, the sling and all fastenings and attachments were not being inspected for damage or defects by a competent person designated by the employer:  (a)  On or about December 2, 2015, employees were exposed to struck by and crushing hazards due to the employer not inspecting the alloy steel chain slings prior to use.  Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.184 E01

Other-than-serious 3 instances 2 exposed
Issued
Jan 6, 2016
Abate by
Jan 14, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach:  (a)  On or about December 2, 2015, employees were exposed to struck by and crushing hazards in that the size, rated capacity, grade and reach of the slings were unknown.  Abatement Note:  Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.305 A02 IX

Deleted Other-than-serious 3 instances 25 exposed
Issued
Jan 6, 2016
Abate by
Jan 19, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard:  (a) On or about December 2, 2015, and at times prior, workers were exposed to hazards of contact with mercury, glass shards, and live electrical conductors resulting from three unguarded fluorescent light fixtures attached at a height of 82 inches.  Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).