1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: JYOTI AMERICAS, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of JYOTI AMERICAS, LLC in 3575 POLLOCK DR., CONROE, TX 77303 (NAICS 332312). OSHA activity number 341096063.

Watch Jyoti Americas, LLC — free Get an email when a new federal OSHA severe-injury report for Jyoti Americas, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
JYOTI AMERICAS, LLC
Site address
3575 POLLOCK DR.
City
CONROE
State
TX
ZIP
77303
Mailing
3575 POLLOCK DR., CONROE, TX 77303
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332312
Employees
260
Ownership type
A

3 citations on file for this inspection.

1910.95 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $7000.00
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:   On or about January 15, 2016, in the production area, where employees are exposed to hazardous noise levels while operating machinery without the employer having established and administered  a continuing, effective hearing conservation program, whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level (TWA) of 85 decibels measured on the A scale or, equivalently, a dose of fifty percent.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1910.147 C04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $7000.00 · Current $7000.00
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On or about December 3, 2015, in the production area, where employees are exposed to caught in and struck by and electrocution hazards when performing service and maintenance on machinery without procedures having been developed, documented, and utilized for the control of potentially hazardous energy.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1910.147 C06 I

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   On or about December 3, 2015, in the production area, where employees are exposed to caught in and struck by hazards when performing service and maintenance on machinery without the employer having conducted an inspection of the energy control procedure at least annually to ensure the requirements of the standard are being followed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View JYOTI AMERICAS, LLC's full OSHA safety record →