OSHA Inspection: HEP REMODELING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HEP REMODELING, INC. in 93 DOVER DR., DES PLAINES, IL 60016 (NAICS 238160). OSHA activity number 341100170.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch HEP Remodeling, INC. — free Get an email when a new federal OSHA severe-injury report for HEP Remodeling, INC. is published. One employer, no account, unsubscribe in one click.
Site address
93 DOVER DR.
City
DES PLAINES
State
IL
ZIP
60016
Mailing
237 WINTERS DR., MELROSE PARK, IL 60164
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

5 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 6 exposed
Issued
Dec 9, 2015
Abate by
Dec 15, 2015
Penalty
Initial $2,800 · Current $1,640 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):        a)  Employees engaged in roofing activity were not protected from fall hazards while working at an elevation of approximately 25 feet above the ground.       In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $1640
  • — Z (S) $2800

1926.503 A01

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 9, 2015
Abate by
Jan 13, 2016
Penalty
Initial $2,000 · Current $1,180 Reduced
29 CFR 1926.503(a)(1):  The employer did not provide a training program for each employee who might be exposed to fall hazards:         a)  Employer did not provide training to each employee in order to recognize hazards associated with working at an elevation and to understand procedures to control or minimize those hazards.         In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1180
  • — Z (S) $2000

1926.1060 A

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 9, 2015
Abate by
Jan 13, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1060(a):  The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards:      a) Employer did not provide training program to each employee in order to recognize hazards associated with working from ladders, and to understand procedures to control or minimize those hazards.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Dec 9, 2015
Abate by
Dec 15, 2015
Penalty
Initial $2,000 · Current $1,180 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:       a)  An extension ladders used by employees to gain access to the working surface did not have its side rails extended at least 3 feet above the surface.         In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1180
  • — Z (S) $2000

1926.1053 B04

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 9, 2015
Abate by
Dec 15, 2015
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:        a)  The extension ladder was used by four employees simultaneously to access and/or egress the roof.          In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).