Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CHACHO'S GENERAL PARTNER PERRIN BEITEL LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CHACHO'S GENERAL PARTNER PERRIN BEITEL LLC in 4320 INDUSTRIAL CENTER, SAN ANTONIO, TX 78217 (NAICS 722511). OSHA activity number 341102945.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Chacho'S General Partner Perrin Beitel LLC — free Get an email when a new federal OSHA severe-injury report for Chacho'S General Partner Perrin Beitel LLC is published. One employer, no account, unsubscribe in one click.
Site address
4320 INDUSTRIAL CENTER
City
SAN ANTONIO
State
TX
ZIP
78217
Mailing
4320 INDUSTRIAL CENTER, SAN ANTONIO, TX 78217
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722511
Employees
12
Ownership type
A

16 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 7, 2016
Abate by
Mar 20, 2016
Penalty
Initial $2,400 · Current $960 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.  Throughout the maintenance shop: On or about December 03, 2015, employees were exposed to slip, trip, and fall hazards while working in the maintenance shop where broken restaurant equipment, parts etc. were stored in a disorderly manner and for an extended period of time, resulting in an unsanitary environment.
Recent events (2)
  • — I (S) $960
  • — Z (S) $2400

1910.36 G02

Serious Gravity 1 1 instance 4 exposed
Issued
Mar 7, 2016
Abate by
Mar 11, 2016
Penalty
Initial $1,200 · Current $480 Reduced
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points:  Front entrance to office: On or about December 03, 2015, employees were exposed to a fire hazard, while cardboard boxes stored along the exit route, reduced the width of the exit route to less than 28 inches, limiting the means of egress.
Recent events (2)
  • — I (S) $480
  • — Z (S) $1200

1910.215 A02

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 7, 2016
Abate by
Mar 11, 2016
Penalty
Initial $1,600 · Current $640 Reduced
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections:  In the welding area: On or about December 03, 2015, an employee were exposed to a caught-in hazard, while operating a 8" Coolant tray bench grinder without a safety guard that covered the spindle end, nut, and flange.
Recent events (2)
  • — I (S) $640
  • — Z (S) $1600

1910.215 A04

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 7, 2016
Abate by
Mar 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work:  a)  In the welding area: On or about December 03, 2015, an employee were exposed to a struck-by hazard while operating an 8" Coolant tray bench grinder without a work rest installed.  b)  In the fabrication area: On or about December 03, 2015, an employee were exposed to a struck-by hazard while operating an 6" Ryobi bench grinder, Model BGH616, without a work rest installed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 7, 2016
Abate by
Mar 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel  a)  In the welding area: On or about December 03, 2015, an employee were exposed to a struck-by hazard while operating an 8" Coolant tray bench grinder without a peripheral protecting member installed.  b)  In the fabrication area:  On or about December 03, 2015, an employee were exposed to a struck-by hazard while operating an 6" Ryobi bench grinder, Model BGH616, without a peripheral protecting member installed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 7, 2016
Abate by
Mar 11, 2016
Penalty
Initial $1,600 · Current $640 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  Stationary drill press: On or about December 03, 2015, employees were exposed to a caught in hazard, while operating a Stationary drill press, Model 62-68C, which had a unguarded rotating pulley of the power transmission system.
Recent events (2)
  • — I (S) $640
  • — Z (S) $1600

1910.219 E01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 7, 2016
Abate by
Mar 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:  Stationary drill press: On or about December 03, 2015, employees were exposed to a caught in hazard, while operating a stationary drill press, Model 62-68C, while the power transmission system had an unguarded rotating belt.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.243 C01

Serious Gravity 5 2 instances 1 exposed
Issued
Mar 7, 2016
Abate by
Mar 11, 2016
Penalty
Initial $1,600 · Current $640 Reduced
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4):  a)  Welding department: On or about December 03, 2015, an employee was exposed to a struck-by hazard, while using a Chicago 4" Angle grinder, Model 0122070676, while the safety guard was not installed around the wheel.  b)  Fabrication department:  On or about December 03, 2015, an employee was exposed to a struck-by hazard, while using a Dewalt 4 1/2" Angle grinder, Model DWE4120, while the safety guard was not installed around the wheel.
Recent events (2)
  • — I (S) $640
  • — Z (S) $1600

1910.252 B02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 7, 2016
Abate by
Mar 11, 2016
Penalty
Initial $1,600 · Current $640 Reduced
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:  In the maintenance shop: On or about December 03, 2015, employees were exposed to an ultraviolet radiation hazard, while welding was being performed while the welding process was not being performed in an enclosed booth or in a screened off area.
Recent events (2)
  • — I (S) $640
  • — Z (S) $1600

1910.253 B02 II

Serious Gravity 5 4 instances 2 exposed
Issued
Mar 7, 2016
Abate by
Mar 11, 2016
Penalty
Initial $1,600 · Current $640 Reduced
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:  a)  On right side of the hydraulic press: On or about December 03, 2015, employees were exposed to a struck-by hazard, a compressed gas cylinder, compressed gases, N.O.S, Un 1956, used for welding, was observed unsecure and without a valve cap.   b)   On left side of the hydraulic press: On or about December 03, 2015, employees were exposed to a struck-by hazard, a compressed gas cylinder, compressed gases, Nitrogen, Un 1066, used for welding, was observed unsecure and without a valve cap.  c)  In the welding area: On or about December 03, 2015, employees were exposed to a struck-by hazard, compressed gas cylinders, approximately 5 bottles (oxygen, acetylene, argon, etc.), used for welding, were observed been stored unsecure.  d)  In the welding area, next to the Miller, Gas Tungsten/Shielded metal Arc Welder: On or about December 03, 2015, employees were exposed to a struck-by hazard, a compressed gas cylinder, Argon, UN1006, used for welding, was observed unsecure.
Recent events (2)
  • — I (S) $640
  • — Z (S) $1600

1910.253 B04 III

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 7, 2016
Abate by
Mar 11, 2016
Penalty
Initial $1,600 · Current $640 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:  In the welding area: On or about December 03, 2015, employees were exposed to a fire hazard due to an oxygen compressed gas cylinders, stored next to an acetylene (fuel gas) compressed gas cylinder.
Recent events (2)
  • — I (S) $640
  • — Z (S) $1600

1910.303 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 7, 2016
Abate by
Mar 11, 2016
Penalty
Initial $1,600 · Current $640 Reduced
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided:  Near the hydraulic press: On or about December 03, 2015, employees were exposed to an electrical hazard, from a 220 Vac receptacle pendant, which was installed via a metal flexible conduit, while the conduit was pulled apart exposing the internal wiring.
Recent events (2)
  • — I (S) $640
  • — Z (S) $1600

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 7, 2016
Abate by
Mar 11, 2016
Penalty
Initial $1,200 · Current $480 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  In front of the shear: On or about December 03, 2015, employees were exposed to an electrical hazard, from two 120 Vac receptacle pendant, which was installed via a flexible cable, while the outer jacket was pulled away exposing the internal wiring.  The receptacle pendant boxes, were not design to be used in this type of application.
Recent events (2)
  • — I (S) $480
  • — Z (S) $1200

1910.303 G02 I

Serious Gravity 10 2 instances 2 exposed
Issued
Mar 7, 2016
Abate by
Mar 11, 2016
Penalty
Initial $2,800 · Current $1,120 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  a)  In the welding department: On or about December 03, 2015, employees were exposed to an electrical hazard, while using a Miller Thunderbolt AC/DC Arc Welder, Model 902775, while the equipment was being operated with the cabinet, that encloses live parts, removed.  b)  Load center next to spot welder:  On or about December 03, 2015, employees were exposed to an electrical hazard, while a 120/240Vac Cutler-Hammer Load Center was in use, without the load center's dead front installed.
Recent events (2)
  • — I (S) $1120
  • — Z (S) $2800

1910.305 B02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 7, 2016
Abate by
Mar 11, 2016
Penalty
Initial $1,600 · Current $640 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  Near the door separating the maintenance shop from the office area: On or about December 03, 2015, a light switch was permanently mounted to the wall and did not have a faceplate installed.  Also above this light switch, permanently mounted to the wall, was a junction box, which did not have a cover installed.
Recent events (2)
  • — I (S) $640
  • — Z (S) $1600

1910.305 G02 III

Serious Gravity 5 3 instances 2 exposed
Issued
Mar 7, 2016
Abate by
Mar 11, 2016
Penalty
Initial $1,600 · Current $640 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a)  Near the hydraulic press: On or about December 03, 2015, employees were exposed to an electrical hazard, from a 220 Vac receptacle pendant, which was installed via a flexible cord, while the outer jacket of the cord was pulled away for the receptacle exposing the cords internal wiring and allowing pull to be directly transmitted to the terminal screws.  b)  Behind the hydraulic press: On or about December 03, 2015, employees were exposed to an electrical hazard, from a 220 Vac plug of the Acme Spot Welder, which was being powered via a flexible cord, while the outer jacket of the cord was pulled away for the plug exposing the cords internal wiring and allowing pull to be directly transmitted to the terminal screws.  c)  In the maintenance shop:  On or about December 03, 2015, employees were exposed to an electrical hazard, from a 220 Vac receptacle used to power the Miller Arc Welder, Model 250AC/DC-HF.  The receptacle's outlet box received power a flexible conduit, which had pulled away from the outlet box exposing the internal wiring and allowing pull to be directly transmitted to the terminal screws.
Recent events (2)
  • — I (S) $640
  • — Z (S) $1600

View Chacho'S General Partner Perrin Beitel LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341102945.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.