Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RAMOS CONSTRUCTION FRAMING CONTRACTOR

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RAMOS CONSTRUCTION FRAMING CONTRACTOR in 7025 N 198TH, OWASSO, OK 74055 (NAICS 238130). OSHA activity number 341103703.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ramos Construction Framing Contractor — free Get an email when a new federal OSHA severe-injury report for Ramos Construction Framing Contractor is published. One employer, no account, unsubscribe in one click.
Site address
7025 N 198TH
City
OWASSO
State
OK
ZIP
74055
Mailing
636 W 79TH STREET, TULSA, OK 74132
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 24, 2016
Abate by
Mar 28, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   On or about December 7, 2015, employees engaged in residential construction greater than 6 feet above ground/lower level were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection. Employees were exposed to the hazard of falls.
Recent events (1)
  • — Z (S) $2800

1926.503 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 24, 2016
Abate by
Apr 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:   On or about December 7, 2015, employees exposed to fall hazards were not provided a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards.  Employees were exposed to the hazard of falls.
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 24, 2016
Abate by
Mar 28, 2016
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  On or about December 7, 2015, portable ladder used for access to an upper landing did not extend 3 feet above the upper landing surface.  Employees were exposed to the hazard of falls.
Recent events (1)
  • — Z (S) $1200

View Ramos Construction Framing Contractor's full OSHA safety record →