Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FLUE TECH, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FLUE TECH, INC. in 21 OGDEN AVE., WHITE PLAINS, NY 10601 (NAICS 238140). OSHA activity number 341105054.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Flue Tech, INC. — free Get an email when a new federal OSHA severe-injury report for Flue Tech, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
FLUE TECH, INC.
Site address
21 OGDEN AVE.
City
WHITE PLAINS
State
NY
ZIP
10601
Mailing
463 LIVINGSTON STREET, SUITE 102, NORWOOD, NJ 07648
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.21 B02

Serious Gravity 5 3 instances 3 exposed
Issued
Dec 31, 2015
Abate by
Jan 28, 2016
Penalty
Initial $2,000 · Current $1,010 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    On or about 12/8/2015,  21 Ogden Ave.    a) Employees were brick pointing the chimney and grinding the joints. They were not provided safety and health training as required by the standard.
Recent events (2)
  • — I (S) $1010
  • — Z (S) $2000

1926.100 A

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 31, 2015
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    On 12/8/2015, 21 Ogden Ave.    a) Employees were brick pointing and grinding joints on the chimney. The two employees below were not wearing protective helmets.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.501 B11

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 31, 2015
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:    On or about 12/8/2015, 21 Ogden Ave.    a) An employee was brick pointing the top portion of the chimney. He was not protected from falling approximately 28' to the ground below.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 31, 2015
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder:    On or about 12/8/2015, 21 Ogden Ave.    a) An employee used an aluminum extension ladder to gain access to the roof. The ladder was not secured and did not extend three feet above the landing.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1926.1053 B12

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 31, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.1053(b)(12): Ladders used where the employee or the ladder could contact exposed energized electrical equipment did not have nonconductive side rails:    On or about 12/8/2015, 21 Ogden Ave.    a) An employee used an aluminum extension ladder without nonconductive side rails to gain access to the roof. The ladder was placed right at the main electrical service panel. The employee was exposed to coming in contact with the energized system.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341105054.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.