DONALDSONVILLE, LA —
OSHA Inspection: CB&I GOVERNMENT SOLUTIONS
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of CB&I GOVERNMENT SOLUTIONS in 39018 HWY 3089, DONALDSONVILLE, LA 70346 (NAICS 541620). OSHA activity number 341107001.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CB&I GOVERNMENT SOLUTIONS
- Site address
- 39018 HWY 3089
- City
- DONALDSONVILLE
- State
- LA
- ZIP
- 70346
- Mailing
- 4171 ESSEN LANE, BATON ROUGE, LA 70809
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 541620
- Employees
- 600
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.1203 E02 III
- Issued
- May 23, 2016
- Abate by
- Jun 25, 2016
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1926.1203(e)(2)(iii): Before an employee enters the space, the internal atmosphere must be tested, with a calibrated direct-reading instrument, for oxygen content, for flammable gases and vapors, and for potential toxic air contaminants, in that order. Any employee who enters the space, or that employee's authorized representative, must be provided an opportunity to observe the pre-entry testing required by this paragraph. a) T-501 Absorption Tower, CF Industries, Donaldsonville, LA; On or about December 4, 2015, the employer failed to perform atmospheric testing of the entire inside of a vessel before employees entered the confine space to perform work activities.
Recent events (3)
- — F (O) $7000
- — C (S) $7000
- — Z (S) $7000
1926.1203 E02 V B
- Issued
- May 23, 2016
- Abate by
- Jun 25, 2016
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1926.1203(e)(2)(v)(B): The forced air ventilation must be so directed as to ventilate the immediate areas where an employee is or will be present within the space and must continue until all employees have left the space: a) T-501 Absorption Tower, CF Industries, Donaldsonville, LA; On or about December 4, 2015, the employer failed to ensure that forced air ventilation in the confined space vessel was arranged in a manner to prevent the accumulation of toxic vapors where employees were present.
Recent events (3)
- — F (O) $7000
- — C (S) $7000
- — Z (S) $7000
More inspections at CB&I Government Solutions