OSHA Inspection: DALLAS 1 CORPARATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DALLAS 1 CORPARATION in INTER SECTION OF W. CASS AND N. BOULOVARD, TAMPA, FL 33606 (NAICS 237110). OSHA activity number 341108819.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dallas 1 Corparation for free Get an email when a new federal OSHA severe-injury report for Dallas 1 Corparation is published. One employer, no account, unsubscribe in one click.
Site address
INTER SECTION OF W. CASS AND N. BOULOVARD
City
TAMPA
State
FL
ZIP
33606
Mailing
P.O. BOX 249, THONOTOSASSA, FL 33592
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
106
Ownership type
Private (A)

2 citations on file for this inspection.

1926.651 C

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Mar 6, 2016
Abate by
Mar 11, 2016
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1926.651(c): Means of egress from trench excavations.  A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.  a. At the site, employees were exposed to a crushed by hazard, in that,  no ladder was provided as a means of access  or egress in in a trench or excavation 7 feet 8 inches deep and 14 feet wide, on or about 12/09/2015.
Recent events (2)
  • · I (S) $0
  • · Z (S) $6300

1926.652 A01

Other-than-serious 1 instance 2 exposed
Issued
Mar 6, 2016
Abate by
Apr 21, 2016
Penalty
Initial $6,300 · Current $6,300
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or 1926.652(c):         a. At the site employees were exposed to a crushed by hazard, in that, no protective system was used while laying pipe within an unprotected (trench or excavation) that was 7 feet 8 inches deep, 13 feet wide and sloped at a 45 degrees in type C soil, on or about 12/09/2015.