Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CUDD PRESSURE CONTROL, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CUDD PRESSURE CONTROL, INC. in 13902 SUNSET BOULEVARD, WILLISTON, ND 58801 (NAICS 213112). OSHA activity number 341110708.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cudd Pressure Control, INC. — free Get an email when a new federal OSHA severe-injury report for Cudd Pressure Control, INC. is published. One employer, no account, unsubscribe in one click.
Site address
13902 SUNSET BOULEVARD
City
WILLISTON
State
ND
ZIP
58801
Mailing
2828 TECHNOLOGY FOREST BOULEVARD, THE WOODLANDS, TX 77381
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
27
Ownership type
A

2 citations on file for this inspection.

1910.106 D05 I

Other-than-serious 1 instance 2 exposed
Issued
Jan 27, 2016
Abate by
Feb 2, 2016
Penalty
Initial $5,000 · Current $5,000

Hazardous substances 10601560166018101911

1910.106(d)(5)(i): Flammable liquids, including stock for sale shall not be stored so as to limit use of exits, stairways, or areas normally used for the safe egress of people.     (a) On or about December 9, 2015 and at times prior for employees exposed to hazard of limited use of exits or areas normally used for the safe egress of people where fifty-eight (58) - three-hundred-twenty (320) gallon intermediate bulk containers containing an approximate total of 15,000 gallons of Category 2 and 3 flammable liquids were stored within a service bay at or near, 13902 Sunset Boulevard in Williston, North Dakota.
Recent events (3)
  • — C (S) $5000
  • — F (O) $5000
  • — Z (S) $5000

1910.106 E06 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jan 27, 2016
Abate by
Feb 2, 2016
Penalty
Initial $0 · Current $0

Hazardous substances 10601560166018101911

29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors from sources such as open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat:  (a) On or about December 9, 2015 and at times prior for employees exposed to potential fire hazards where five - 320 gallon and 53 - 320 gallon intermediate bulk containers containing an approximate total of 15,000 gallons of Category 2 and 3 flammable liquids were stored within a service bay adjacent to lighting and wiring which was not rated as explosion proof at or near, 13902 Sunset Boulevard in Williston, North Dakota.
Recent events (3)
  • — C (S) $0
  • — F (S) $0
  • — Z (S) $0

View Cudd Pressure Control, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341110708.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.