SAINT JOSEPH, MO —
OSHA Inspection: RECYCLING CORP OF ST. JOSEPH
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of RECYCLING CORP OF ST. JOSEPH in 801 S. 8TH ST, SAINT JOSEPH, MO 64501 (NAICS 423930). OSHA activity number 341112951.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RECYCLING CORP OF ST. JOSEPH
- Site address
- 801 S. 8TH ST
- City
- SAINT JOSEPH
- State
- MO
- ZIP
- 64501
- Mailing
- P.O. BOX 564, SAINT JOSEPH, MO 64501
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Apr 21, 2016
- Abate by
- May 24, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) The employer failed to develop, document and utilize specific procedures to control potentially hazardous energy of the baling machines such as electrical hydraulic and kinetic energies. Employees were exposed to crushing injuries and electrical hazards, such as shock and/or burns, when performing maintenance or removing jams from the baling machines.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.305 D02
- Issued
- Apr 21, 2016
- Penalty
- Initial $4,900 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets, cutout boxes, or enclosures designed for the purpose and dead front. However, panelboards other than the dead front externally-operable type are permitted where accessible only to qualified persons: a) The panelboard located in the Northeast corner of the building, was mounted in a cabinet or enclosure designed for the purpose, but was not dead front. Employees were exposed to live electrical parts and associated electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $4900
1910.305 G01 IV
- Issued
- Apr 21, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv): (a) The employer failed to ensure that flexible cords were not passed through walls; Flexible cord powering the exterior lighting passed through holes drilled into the south cinder block wall. Employees were exposed to electrical hazards such as shock and fire.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
More inspections in this industry (NAICS 423930)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341112951.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.