WORCESTER, MA —
OSHA Inspection: RAYNOR OVERHEAD DOOR INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of RAYNOR OVERHEAD DOOR INC. in WORCESTER ACADEMY 14 MARION AVE, WORCESTER, MA 01605 (NAICS 238290). OSHA activity number 341114114.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAYNOR OVERHEAD DOOR INC.
- Site address
- WORCESTER ACADEMY 14 MARION AVE
- City
- WORCESTER
- State
- MA
- ZIP
- 01605
- Mailing
- 46 MILTON ST, WORCESTER, MA 01605
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238290
- Employees
- 12
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 11, 2016
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not establish employment and a place of employment free from recognized hazards that were causing or likely to cause death or serious physical harm in that employee(s) were exposed to the hazard of being struck by the bi-fold door: a) Location: Worcester Academy: On or about December 9, 2015, three employee(s) using a scissor lift to repair the building trim outside the center bi-fold door in the theater did not affix lockout devices or otherwise disable the door to prevent unexpected or unintentional operation of the door. Among other methods, one feasible and reasonable method to correct this hazard would be to implement and enforce the American National Standards Institute's standard for personnel protection-lockout/tagout of energy sources-minimum safety requirements as specified in ANSI Z244.1-2003(R2014). IN THE ALTERNATIVE: 29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) Location: Worcester Academy: On or about December 9, 2015, employee(s) using a scissor lift to repair the building trim outside the center bi-fold door in the theater did not lockout or otherwise disable the bi-fold door to prevent unexpected or unintentional operation of the door.
Recent events (2)
- — I (S) $2800
- — Z (S) $2800
1926.451 F01
- Issued
- Feb 11, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(1): Scaffold and/or scaffold components shall not be loaded in excess of their maximum intended loads or rated capacities, whichever was less. Worcester Academy Theater, 14 Marion Avenue, Worcester, Massachusetts; The Skyjack Scissor Lift, Model SJ1114632, SN 70022724, in use at the site was rated for use by two people and their tools. Three people, including a management employee, and their tools were elevated in the lift exceeding the permitted load of the lift.
Recent events (2)
- — I (O) $0
- — Z (S) $2800
More inspections in this industry (NAICS 238290)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341114114.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.